The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In Situ Polymerization Deposition of Porous Conducting Polymer on Reduced Graphene Oxide for Gas Sensor
Abstract
Porous conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) nanocomposite prepared on reduced graphene oxide (RGO) film was used as efficient chemiresistor sensor platform for NO2 detection. The comparable electrical performance between RGO and porous PEDOT nanostructure, the large surface area and opening porous structure of this RGO/porous PEDOT nanocomposite resulted in excellent synergistic effect. The gas sensing performance revealed that, in contrast to bare RGO, the RGO/porous PEDOT exhibited the enhanced sensitivity (2 orders of magnitude) as well as response and recovery performance. As a result of the highly uniform distribution of PEDOT porous network and excellent synergetic effect between RGO and porous PEDOT, this nanocomposite based sensor exhibited higher selectivity to NO2 in contrast to other oxidant analyte gases, e.g., HCl, H2S and SO2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reduction of graphene oxide via l -ascorbic acid
Zhang, J., Yang, H., Shen, G., Cheng, P., Zhang, J., & Guo, S. (2010) · Chem. Commun. · doi:10.1039/b917705a · Cited by 2,344
Cited by
Yang, S., Jiang, C., & Wei, S.-H. (2017) · Applied Physics Reviews · doi:10.1063/1.4983310 · Cited by 876
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Recent Advances in Electrochemical Sensors for Detecting Toxic Gases: NO2, SO2 and H2S
Khan, M. A. H., Rao, M. V., & Li, Q. (2019) · Sensors · doi:10.3390/s19040905 · Cited by 417
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
Two-dimensional nanomaterial-based field-effect transistors for chemical and biological sensing
Mao, S., Chang, J., Pu, H., Lu, G., He, Q., Zhang, H., & Chen, J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00827e · Cited by 404
Dai, J., Ogbeide, O., Macadam, N., Sun, Q., Yu, W., Li, Y., Su, B.-L., Hasan, T., Huang, X., & Huang, W. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00459a · Cited by 378
Two-dimensional layered nanomaterials for gas-sensing applications
Yang, W., Gan, L., Li, H., & Zhai, T. (2016) · Inorganic Chemistry Frontiers · doi:10.1039/c5qi00251f · Cited by 376
Self-citationGraphene-based hybrids for chemiresistive gas sensors
Meng, F.-L., Guo, Z., & Huang, X.-J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.008 · Cited by 337
Graphene and graphene derivatives toughening polymers: Toward high toughness and strength
Wang, J., Jin, X., Li, C., Wang, W., Wu, H., & Guo, S. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.03.229 · Cited by 333
Three-Dimensional Crumpled Graphene-Based Nanosheets with Ultrahigh NO 2 Gas Sensibility
Chen, Z., Wang, J., Umar, A., Wang, Y., Li, H., & Zhou, G. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b01229 · Cited by 120
Metadata
- Authors
- Yang, Y., Li, S., Yang, W., Yuan, W., Xu, J., & Jiang, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-08-12
- Volume
- 6
- Issue
- 16
- Pages
- 13807-13814
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2074378463
- Cited by
- 170
- References
- 1
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.