The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Enhanced Sensitivity and Stability of Room-Temperature NH3 Sensors Using Core–Shell CeO2 Nanoparticles@Cross-linked PANI with p–n Heterojunctions
Abstract
We report a room-temperature NH3 gas sensor with high response and great long-term stability, including CeO2 NPs conformally coated by cross-linked PANI hydrogel. Such core-shell nanocomposites were prepared by in situ polymerization with different weight ratios of CeO2 NPs and aniline. At room temperature, the nanohybrids showed enhanced response (6.5 to 50 ppm of NH3), which could be attributed to p-n junctions formed by the intimate contact between these two materials. Moreover, the stability was discussed in terms of phytic acid working as a gelator, which helped the PANI sheath accommodate itself and enhance the mechanical strength and chemical stability of the sensors by avoiding "swelling effect" in high relative humidity. The sensors maintained its sensing characteristic (response of ca. 6.5 to 50 ppm of NH3) in 15 days. Herein, the obtained results could help to accelerate the development of ammonia gas sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
Cited by
Nanostructured Materials for Room‐Temperature Gas Sensors
Zhang, J., Liu, X., Neri, G., & Pinna, N. (2016) · Advanced Materials · doi:10.1002/adma.201503825 · Cited by 1,569
Organic–Inorganic Hybrid Nanocomposite-Based Gas Sensors for Environmental Monitoring
Kaushik, A., Kumar, R., Arya, S. K., Nair, M., Malhotra, B. D., & Bhansali, S. (2015) · Chemical Reviews · doi:10.1021/cr400659h · Cited by 534
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
Recent Progress on Flexible Room-Temperature Gas Sensors Based on Metal Oxide Semiconductor
Ou, L.-X., Liu, M.-Y., Zhu, L.-Y., Zhang, D. W., & Lu, H.-L. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00956-9 · Cited by 402
A review on advances in application of polyaniline for ammonia detection
Tanguy, N. R., Thompson, M., & Yan, N. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.11.008 · Cited by 284
Metadata
- Authors
- Wang, L., Huang, H., Xiao, S., Cai, D., Liu, Y., Liu, B., Wang, D., Wang, C., Li, H., Wang, Y., Li, Q., & Wang, T.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-07-31
- Volume
- 6
- Issue
- 16
- Pages
- 14131-14140
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2323460348
- Cited by
- 249
- References
- 1
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.