The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Biodegradable Thermogels
Abstract
All living creatures respond to external stimuli. Similarly, some polymers undergo conformational changes in response to changes in temperature, pH, magnetic field, electrical field, or the wavelength of light. In one type of stimuli-responsive polymer, thermogel polymers, the polymer aqueous solution undergoes sol-to-gel transition as the temperature increases. Drugs or cells can be mixed into the polymer aqueous solution when it is in its lower viscosity solution state. After injection of the solution into a target site, heating prompts the formation of a hydrogel depot in situ, which can then act as a drug releasing system or a cell growing matrix. In this Account, we describe key materials developed in our laboratory for the construction of biodegradable thermogels. We particularly emphasize recently developed polypeptide-based materials where the secondary structure and nanoassembly play an important role in the determining the material properties. This Account will provide insights for controlling parameters, such as the sol-gel transition temperature, gel modulus, critical gel concentration, and degradability of the polymer, when designing a new thermogel system for a specific biomedical application. By varying the stereochemistry of amino acids in polypeptides, the molecular weight of hydrophobic/hydrophilic blocks, the composition of the polypeptides, the hydrophobic end-capping of the polypeptides, and the microsequences of a block copolymer, we have controlled the thermosensitivity and nanoassembly patterns of the polymers. We have investigated a series of thermogel biodegradable polymers. Polymers such as poly(lactic acid-co-glycolic acid), polycaprolactone, poly(trimethylene carbonate), polycyanoacrylate, sebacic ester, polypeptide were used as hydrophobic blocks, and poly(ethylene glycol) and poly(vinyl pyrrolidone) were used as hydrophilic blocks. To prepare a polymer sensitive to pH and temperature, carboxylic acid or amine groups were introduced along the polymer backbone. The sol-gel transition mechanism involves changes in the secondary structures of the hydrophobic polypeptide and in the conformation of the hydrophilic block. The polypeptide copolymers were stable in the phosphate buffered saline, but the presence of proteolytic enzymes such as elastase, cathepsin B, cathepsin C, and matrix metallopreoteinase accelerated their degradation. We also describe several biomedical applications of biogradable thermogel polymers. One subcutaneous injection of the insulin formulation of thermogel polypeptide copolymers in diabetic rats provided hypoglycemic efficacy for more than 16 days. The thermogels also provided a compatible microenvironment for chondrocytes, and these cells produced biomarkers for articular cartilage such as sulfated glucoaminoglycan (sGAG) and type II collagen. The thermogels were also used as a fixing agent for in situ cell imaging, and cellular activities such as endocytosis were observed by live cell microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
Batrakova, E. V., & Kabanov, A. V. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.04.013 · Cited by 1,278
Cited by
25th Anniversary Article: Engineering Hydrogels for Biofabrication
Malda, J., Visser, J., Melchels, F. P., Jüngst, T., Hennink, W. E., Dhert, W. J. A., Groll, J., & Hutmacher, D. W. (2013) · Advanced Materials · doi:10.1002/adma.201302042 · Cited by 1,901
Emerging Role of Hydrogels in Drug Delivery Systems, Tissue Engineering and Wound Management
Jacob, S., Nair, A. B., Shah, J., Sreeharsha, N., Gupta, S., & Shinu, P. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13030357 · Cited by 485
Temperature-responsive compounds as in situ gelling biomedical materials
Moon, H. J., Ko, D. Y., Park, M. H., Joo, M. K., & Jeong, B. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35078e · Cited by 421
Self-citationRecent progress of in situ formed gels for biomedical applications
Ko, D. Y., Shinde, U. P., Yeon, B., & Jeong, B. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.08.002 · Cited by 416
Self-citationPEG-based thermosensitive and biodegradable hydrogels
Shi, J., Yu, L., & Ding, J. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.04.009 · Cited by 341
Metadata
- Authors
- Park, M. H., Joo, M. K., Choi, B. G., & Jeong, B.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-12
- Volume
- 45
- Issue
- 3
- Pages
- 424-433
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W4256413638
- Cited by
- 226
- References
- 3
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biodegradable Thermogels. https://app.cochat.ai/papers/10.1021/ar200162j
- The paper
- Park, M. H., Joo, M. K., Choi, B. G., & Jeong, B. (2012). Biodegradable Thermogels. Accounts of Chemical Research. https://doi.org/10.1021/ar200162j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.