The DOI matches its Crossref record.
Near-Infrared Fluorescent RGD Peptides for Optical Imaging of Integrin αvβ3Expression in Living Mice
Open accessAbstract
Near-infrared fluorescence optical imaging is a powerful technique for studying diseases at the molecular level in preclinical models. We recently reported that monomeric RGD peptide c(RGDyK) conjugated to the NIR fluorescent dye specifically targets integrin receptor both in cell culture and in living subjects. In this report, Cy5.5-conjugated mono-, di-, and tetrameric RGD peptides were evaluated in a subcutaneous U87MG glioblastoma xenograft model in order to investigate the effect of multimerization of RGD peptide on integrin avidity and tumor targeting efficacy. The binding affinities of Cy5.5-conjugated RGD monomer, dimer, and tetramer for alpha(v)beta(3) integrin expressed on U87MG cell surface were determined to be 42.9 +/- 1.2, 27.5 +/- 1.2, and 12.1 +/- 1.3 nmol/L, respectively. All three peptide-dye conjugates had integrin specific uptake both in vitro and in vivo. The subcutaneous U87MG tumor can be clearly visualized with each of these three fluorescent probes. Among them, tetramer displayed highest tumor uptake and tumor-to-normal tissue ratio from 0.5 to 4 h postinjection. Tumor-to-normal tissue ratio for Cy5.5-conjugated RGD monomer, dimer, and tetramer were found to be 3.18 +/- 0.16, 2.98 +/- 0.05, and 3.63 +/- 0.09, respectively, at 4 h postinjection. These results suggest that Cy5.5-conjugated monomeric, dimeric, and tetrameric RGD peptides are all suitable for integrin expression imaging. The multmerization of RGD peptide results in moderate improvement of imaging characteristics of the tetramer, compared to that of the monomer and dimeric counterparts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827
Multimodality Molecular Imaging of Tumor Angiogenesis
Cai, W., & Chen, X. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045922 · Cited by 494
Self-citationWang, J., Tian, S., Petros, R. A., Napier, M. E., & DeSimone, J. M. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1043177 · Cited by 330
Peptides and Peptide Hormones for Molecular Imaging and Disease Diagnosis
Lee, S., Xie, J., & Chen, X. (2010) · Chemical Reviews · doi:10.1021/cr900361p · Cited by 324
Self-citationPeptide-Based Probes for Targeted Molecular Imaging
Lee, S., Xie, J., & Chen, X. (2010) · Biochemistry · doi:10.1021/bi901135x · Cited by 310
Self-citationLi, L., Hou, J., Liu, X., Guo, Y., Wu, Y., Zhang, L., & Yang, Z. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.01.019 · Cited by 289
Self-citationMolecular imaging of the tumor microenvironment
Zhou, Z., & Lu, Z.-R. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.07.012 · Cited by 253
Metadata
- Authors
- Cheng, Z., Wu, Y., Xiong, Z., Gambhir, S. S., & Chen, X.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-10-29
- Volume
- 16
- Issue
- 6
- Pages
- 1433-1441
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W1971145143
- Cited by
- 234
- References
- 0
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.