d-Mannose-Modified Iron Oxide Nanoparticles for Stem Cell Labeling
The DOI matches its Crossref record.
Abstract
New surface-modified iron oxide nanoparticles were developed by precipitation of Fe(II) and Fe(III) salts with ammonium hydroxide according to two methods. In the first method, precipitation was done in the presence of D-mannose solution (in situ coating); the second method involved oxidation of precipitated magnetite with sodium hypochlorite followed by addition of D-mannose solution (postsynthesis coating). Selected nanoparticles were characterized by transmission electron microscopy (TEM), atomic force microscopy (AFM), elemental analysis, dynamic light scattering, infrared (IR), X-ray powder analysis, and ultrasonic spectrometry. While the first preparation method produced very fine nanoparticles ca. 2 nm in diameter, the second one yielded ca. 6 nm particles. Addition of D-mannose after synthesis did not affect the iron oxide particle size. UV-vis spectroscopy suggested that D-mannose suppresses the nonspecific sorption of serum proteins from DMEM culture medium on magnetic nanoparticles. Rat bone marrow stromal cells (rMSCs) were labeled with uncoated and d-mannose-modified iron oxide nanoparticles and with Endorem (Guerbet, France; control). Optical and transmission electron microscopy confirmed the presence of D-mannose-modified iron oxide nanoparticles inside the cells. D-mannose-modified nanoparticles crossed the cell membranes and were internalized well by the cells. Relaxivity measurements of labeled cells in gelatin revealed very high relaxivities only for postsynthesis D-mannose-coated iron oxide nanoparticles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Superparamagnetic iron oxide nanoparticles: magnetic nanoplatforms as drug carriers
Wahajuddin, & Arora (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s30320 · Cited by 1,117
Li, L., Jiang, W., Luo, K., Song, H., Lan, F., Wu, Y., & Gu, Z. (2013) · Theranostics · doi:10.7150/thno.5366 · Cited by 491
Atherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles
Cormode, D. P., Roessl, E., Thran, A., Skajaa, T., Gordon, R. E., Schlomka, J.-P., Fuster, V., Fisher, E. A., Mulder, W. J. M., Proksa, R., et al. (2010) · Radiology · doi:10.1148/radiol.10092473 · Cited by 479
Cell membrane-derived nanomaterials for biomedical applications
Fang, R. H., Jiang, Y., Fang, J. C., & Zhang, L. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.02.041 · Cited by 468
Targeted magnetic iron oxide nanoparticles for tumor imaging and therapy
Dong, S. (2008) · International Journal of Nanomedicine · doi:10.2147/ijn.s2824 · Cited by 464
Metadata
- Authors
- Horák, D., Babič, M., Jendelová, P., Herynek, V., Trchová, M., Pientka, Z., Pollert, E., Hájek, M., & Syková, E.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-03-20
- Volume
- 18
- Issue
- 3
- Pages
- 635-644
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W1965689191
- Cited by
- 135
- References
- 0
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: d-Mannose-Modified Iron Oxide Nanoparticles for Stem Cell Labeling. https://app.cochat.ai/papers/10.1021/bc060186c
- The paper
- Horák, D., Babič, M., Jendelová, P., Herynek, V., Trchová, M., Pientka, Z., Pollert, E., Hájek, M., & Syková, E. (2007). d-Mannose-Modified Iron Oxide Nanoparticles for Stem Cell Labeling. Bioconjugate Chemistry. https://doi.org/10.1021/bc060186c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.