Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Effect of Chain Length on the Formation and Stability of Synthetic .alpha.-Helical Coiled Coils

Su, Jeffrey Y., Hodges, Robert S., Kay, Cyril M.·1994·Biochemistry

Abstract

A series of polypeptides containing 9, 12, 16, 19, 23, 26, 30, 33, and 35 amino acid residues was designed to investigate the effects of peptide chain length on the formation and stability of two-stranded alpha-helical dimers or coiled coils. These peptides were synthesized by the solid-phase method, purified by reversed-phase high-performance liquid chromatography (RP-HPLC), and characterized by RP-HPLC, amino acid composition analysis, and mass spectrometry. The amphipathic alpha-helical peptides were designed to dimerize by interchain hydrophobic interactions at positions a and d and interchain salt bridges between lysine and glutamic acid residues at positions e and g of the repeating heptad sequence of Glu-Ile-Glu-Ala-Leu-Lys-Ala (g-a-b-c-d-e-f). The ability of these peptides to form alpha-helical structures in the presence and absence of a helix-inducing reagent (trifluoroethanol) was monitored by circular dichroism spectroscopy. The helicity of the peptides increased with increasing chain length in a cooperative manner. A minimum of three heptads corresponding to six helical turns was required for a peptide to adopt the two-stranded alpha-helical coiled coil conformation in aqueous medium. The increased stability of the peptides as a result of an increase in hydrophobic interactions (chain length) was demonstrated by the shift in the transitions of the guanidine hydrochloride (Gdn.HCl) denaturation and thermal unfolding profiles. The concentrations of denaturant (Gdn.HCl) required to achieve 50% denaturation are 3.2, 4.9, 6.9, and 7.5 M for peptides 23r, 26r, 30r, and 33r, respectively, in aqueous medium. However, the effect of a chain length increase on coiled-coil stability was not additive. The melting temperature, Tm, at which 50% of the helicity is lost, increased by 34 degrees C in changing the peptide chain length from 23 to 26; however, that shift was only 14 degrees C when the chain length was increased from 30 to 33 residues. These results are consistent with a chain length dependent cooperative folding of the peptides into coiled coils.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/bi00255a032

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 244

Metadata

Authors
Su, J. Y., Hodges, R. S., & Kay, C. M.
Venue
Biochemistry
Published
1994-12-01
Volume
33
Issue
51
Pages
15501-15510
ISSN
  • 0006-2960 (ISSN-L)
  • 1520-4995
OpenAlex
W2042475922
Cited by
244
References
3
FWCI
2.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.