The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Novel multilayered lipid vesicles: comparison of physical characteristics of multilamellar liposomes and stable plurilamellar vesicles
Abstract
The preparation of a new kind of multilayered liposome, called a stable plurilamellar vesicle (SPLV), is described. Although SPLVs and classical multilamellar vesicles (MLVs) are made of the same materials and appear overtly similar in the electron microscope, the two types of vesicles differ as determined by stability, entrapment efficiency, electron spin resonance (ESR), NMR, X-ray diffraction, and biological effects. It is demonstrated that, contrary to what has been assumed, classical MLVs exclude solutes during their formation and, thus, are under a state of osmotic compression. By contrast, the SPLV process produces liposomes that are not compressed. The effects of osmotic compression are discussed. It is suggested that the state of osmotic stress is an important variable that distinguishes various types of liposomes and that has significant physical and biological consequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion of univalent ions across the lamellae of swollen phospholipids
Bangham, A. D., Standish, M. M., & Watkins, J. C. (1965) · Journal of Molecular Biology · doi:10.1016/s0022-2836(65)80093-6 · Cited by 4,664
INTERACTIONS BETWEEN NEUTRAL PHOSPHOLIPID BILAYER MEMBRANES
LIS, L. J., MCALISTER, M., FULLER, N., RAND, R. P., & PARSEGIAN, V. A. (1982) · Biophysical Journal · doi:10.1016/s0006-3495(21)00385-4 · Cited by 758
Cited by
Vesicles of variable sizes produced by a rapid extrusion procedure
Mayer, L. D., Hope, M. J., & Cullis, P. R. (1986) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(86)90302-0 · Cited by 1,691
Liposomes in drug delivery: Progress and limitations
Sharma, A. (1997) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(97)00135-x · Cited by 1,253
Essential oils: From extraction to encapsulation
Asbahani, A. E., Miladi, K., Badri, W., Sala, M., Addi, E. H. A., Casabianca, H., Mousadik, A. E., Hartmann, D., Jilale, A., Renaud, F. N. R., et al. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.12.069 · Cited by 1,065
Haran, G., Cohen, R., Bar, L. K., & Barenholz, Y. (1993) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(93)90105-9 · Cited by 934
Giant Vesicles: Preparations and Applications
Walde, P., Cosentino, K., Engel, H., & Stano, P. (2010) · ChemBioChem · doi:10.1002/cbic.201000010 · Cited by 770
Liposomes: Advancements and innovation in the manufacturing process
Shah, S., Dhawan, V., Holm, R., Nagarsenker, M. S., & Perrie, Y. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.002 · Cited by 745
Lipid-Based Drug Delivery Systems in Cancer Therapy: What Is Available and What Is Yet to Come
Yingchoncharoen, P., Kalinowski, D. S., & Richardson, D. R. (2016) · Pharmacological Reviews · doi:10.1124/pr.115.012070 · Cited by 744
Novel methods for liposome preparation
Patil, Y. P., & Jadhav, S. (2014) · Chemistry and Physics of Lipids · doi:10.1016/j.chemphyslip.2013.10.011 · Cited by 638
Interactions of sugars with membranes
Crowe, J. H., Crowe, L. M., Carpenter, J. F., Rudolph, A. S., Wistrom, C. A., Spargo, B. J., & Anchordoguy, T. J. (1988) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(88)90015-9 · Cited by 626
Preparation and characterization of liposomes as therapeutic delivery systems: a review
Vemuri, S., & Rhodes, C. T. (1995) · Pharmaceutica Acta Helvetiae · doi:10.1016/0031-6865(95)00010-7 · Cited by 564
Non-ionic surfactant vesicles (niosomes): Physical and pharmaceutical chemistry
Uchegbu, I. F., & Florence, A. T. (1995) · Advances in Colloid and Interface Science · doi:10.1016/0001-8686(95)00242-i · Cited by 467
Sustainable technologies for liposome preparation
Maja, L., Željko, K., & Mateja, P. (2020) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2020.104984 · Cited by 398
Liposomes as biocompatible and smart delivery systems – the current state
Dymek, M., & Sikora, E. (2022) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2022.102757 · Cited by 392
Prenner, E., & Chiu, M. (2011) · Journal of Pharmacy And Bioallied Sciences · doi:10.4103/0975-7406.76463 · Cited by 373
Liposomes: Preparation, Characterization, and Preservation
Lichtenberg, D., & Barenholz, Y. (1988) · Methods of Biochemical Analysis · doi:10.1002/9780470110546.ch7 · Cited by 289
Doxorubicin physical state in solution and inside liposomes loaded via a pH gradient
Li, X., Hirsh, D. J., Cabral-Lilly, D., Zirkel, A., Gruner, S. M., Janoff, A. S., & Perkins, W. R. (1998) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(98)00175-8 · Cited by 259
Self-citation
Metadata
- Authors
- Gruner, S. M., Lenk, R. P., Janoff, A. S., & Ostro, N. J.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1985-06-04
- Volume
- 24
- Issue
- 12
- Pages
- 2833-2842
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W2006648837
- Cited by
- 186
- References
- 2
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.