The DOI matches its Crossref record.
1-[4-(Trimethylamino)phenyl]-6-phenylhexa-1,3,5-triene: synthesis, fluorescence properties and use as a fluorescence probe of lipid bilayers
Abstract
1-[4-(Trimethylamino)phenyl]-6-phenylhexa-1,3,5-triene (TMA-DPH), a cationic analogue of diphenylhexatriene (DPH), has photophysical properties that are generally similar to those of DPH. In solution the fluorescence lifetime (tau) of TMA-DPH is short (less than 1.5 ns), but tau increases to approximately 7 ns when the probe is embedded in lipid bilayers at temperatures less than the thermal transition temperature (Tc) of the lipid. The cationic charge ensures that the probe is anchored at the lipid-water interface, most likely with the DPH moiety intercalated between the upper portions of the fatty acyl chains. The profiles of changes in steady-state anisotropies (rss) and limiting hindered anisotropies (r infinity) are similar for both TMA-DPH and DPH embedded in lipid bilayers, but r infinity values for TMA-DPH even at T much greater than Tc are generally greater than 0.14, e.g., at 35 degrees C in 1,2-dimyristoylglycero-3-phosphocholine (DMPC) (cf. 0.03 for DPH in DMPC at 35 degrees C). Electrostatic interactions of the cationic probe with head groups of phospholipids do not appear to significantly influence the apparent dynamics of the probe. TMA-DPH should prove useful in the study of the dynamics of phospholipid monolayers, e.g., in native or reconstituted lipoproteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence method for measuring the kinetics of fusion between biological membranes
Hoekstra, D., De Boer, T., Klappe, K., & Wilschut, J. (1984) · Biochemistry · doi:10.1021/bi00319a002 · Cited by 677
Use of fluorescent probes to monitor molecular order and motions within liposome bilayers
Lentz, B. R. (1993) · Chemistry and Physics of Lipids · doi:10.1016/0009-3084(93)90060-g · Cited by 386
Role of cholesterol in the function and organization of G-protein coupled receptors
Pucadyil, T. J., & Chattopadhyay, A. (2006) · Progress in Lipid Research · doi:10.1016/j.plipres.2006.02.002 · Cited by 296
Melo, J. B., Agostinho, P., & Oliveira, C. R. (2003) · Neuroscience Research · doi:10.1016/s0168-0102(02)00201-8 · Cited by 271
Batrakova, E. V., Li, S., Alakhov, V. Y., Miller, D. W., & Kabanov, A. V. (2003) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1124/jpet.102.043307 · Cited by 263
Abe, F., Usui, K., & Hiraki, T. (2009) · Biochemistry · doi:10.1021/bi900578y · Cited by 107
Rye, K.-A., Hime, N. J., & Barter, P. J. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.1.189 · Cited by 65
Metadata
- Authors
- Prendergast, F. G., Haugland, R. P., & Callahan, P. J.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1981-12-01
- Volume
- 20
- Issue
- 26
- Pages
- 7333-7338
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W1991079346
- Cited by
- 492
- References
- 0
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.