The DOI matches its Crossref record.
Direct microsequence analysis of polypeptides using an improved sequenator, a nonprotein carrier (Polybrene), and high pressure liquid chromatography
Abstract
We have combined the use of a nonprotein carrier (Polybrene), high pressure liquid chromatography, and modifications in Edman chemistry with the improvements of a commercial spinning cup sequenator suggested by Wittmann-Liebold [Wittmann-Liebold, B. (1973) Hoppe-Seyler's Z. Physiol. Chem. 354, 1415] to analyze amino acid phenylthiohydantoins obtained from automated Edman degradation of microquantities of polypeptide directly without the use of radiolabel. This approach has allowed us to determine the sequence of the N-terminal 47 residues of sperm whale myoglobin starting with 200 pmol of protein, 77 residues of an antibody light chain with 5 nmole of protein, and 54 residues of an antibody heavy chain with 8 nmol of protein. In addition, we completely sequenced a hydrophobic 14-residue peptide at the 1.5-nmol level. Our technique of direct analysis for microsamples is capable of providing routine, extende N-terminal sequence analysis for nanomole and subnanomole levels of polypeptides and protines, and it also is applicable to analysis of more classical sample quantities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dynorphin-(1-13), an extraordinarily potent opioid peptide.
Goldstein, A., Tachibana, S., Lowney, L. I., Hunkapiller, M., & Hood, L. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.12.6666 · Cited by 882
Self-citation[36] High-sensitivity sequencing with a gas-phase sequenator
Hunkapiller, M. W., Hewick, R. M., Dreyer, W. J., & Hood, L. E. (1983) · Methods in Enzymology · doi:10.1016/s0076-6879(83)91038-8 · Cited by 659
Self-citationPrimary structure of corticotropin-releasing factor from ovine hypothalamus
Spiess, J., Rivier, J., Rivier, C., & Vale, W. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.10.6517 · Cited by 424
MacGillivray, R. T., Mendez, E., Shewale, J. G., Sinha, S. K., Lineback-Zins, J., & Brew, K. (1983) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)32696-6 · Cited by 275
Metadata
- Authors
- Hunkapiller, M. W., & Hood, L. E.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1978-05-30
- Volume
- 17
- Issue
- 11
- Pages
- 2124-2133
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W2016266875
- Cited by
- 383
- References
- 0
- FWCI
- 45.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct microsequence analysis of polypeptides using an improved sequenator, a nonprotein carrier (Polybrene), and high pressure liquid chromatography. https://app.cochat.ai/papers/10.1021/bi00604a016
- The paper
- Hunkapiller, M. W., & Hood, L. E. (1978). Direct microsequence analysis of polypeptides using an improved sequenator, a nonprotein carrier (Polybrene), and high pressure liquid chromatography. Biochemistry. https://doi.org/10.1021/bi00604a016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.