Microtubule Structure at Improved Resolution
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Microtubule architecture can vary with eukaryotic species, with different cell types, and with the presence of stabilizing agents. For in vitro assembled microtubules, the average number of protofilaments is reduced by the presence of sarcodictyin A, epothilone B, and eleutherobin (similarly to taxol) but increased by taxotere. Assembly with a slowly hydrolyzable GTP analogue GMPCPP is known to give 96% 14 protofilament microtubules. We have used electron cryomicroscopy and helical reconstruction techniques to obtain three-dimensional maps of taxotere and GMPCPP microtubules incorporating data to 14 A resolution. The dimer packing within the microtubule wall is examined by docking the tubulin crystal structure into these improved microtubule maps. The docked tubulin and simulated images calculated from "atomic resolution" microtubule models show tubulin heterodimers are aligned head to tail along the protofilaments with the beta subunit capping the microtubule plus end. The relative positions of tubulin dimers in neighboring protofilaments are the same for both types of microtubule, confirming that conserved lateral interactions between tubulin subunits are responsible for the surface lattice accommodation observed for different microtubule architectures. Microtubules with unconventional protofilament numbers that exist in vivo are likely to have the same surface lattice organizations found in vitro. A curved "GDP" tubulin conformation induced by stathmin-like proteins appears to weaken lateral contacts between tubulin subunits and could block microtubule assembly or favor disassembly. We conclude that lateral contacts between tubulin subunits in neighboring protofilaments have a decisive role for microtubule stability, rigidity, and architecture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recognition of Unique Carboxyl-Terminal Motifs by Distinct PDZ Domains
Songyang, Z., Fanning, A. S., Fu, C., Xu, J., Marfatia, S. M., Chishti, A. H., Crompton, A., Chan, A. C., Anderson, J. M., & Cantley, L. C. (1997) · Science · doi:10.1126/science.275.5296.73 · Cited by 1,385
Cited by
Mechanisms of Taxol resistance related to microtubules
Orr, G. A., Verdier-Pinard, P., McDaid, H., & Horwitz, S. B. (2003) · Oncogene · doi:10.1038/sj.onc.1206934 · Cited by 727
“Recently, models with improved resolution have been published (Lowe et al., 2001; Meurer-Grob et al., 2001).”
BackgroundMechanisms of drug release in nanotherapeutic delivery systems
Wong, P. T., & Choi, S. K. (2015) · Chemical Reviews · doi:10.1021/cr5004634 · Cited by 507
The oncoprotein 18/stathmin family of microtubule destabilizers
Cassimeris, L. (2002) · Current Opinion in Cell Biology · doi:10.1016/s0955-0674(01)00289-7 · Cited by 432
Microtubule Structure at 8 Å Resolution
Li, H., DeRosier, D. J., Nicholson, W. V., Nogales, E., & Downing, K. H. (2002) · Structure · doi:10.1016/s0969-2126(02)00827-4 · Cited by 413
EBs Recognize a Nucleotide-Dependent Structural Cap at Growing Microtubule Ends
Maurer, S. P., Fourniol, F. J., Bohner, G., Moores, C. A., & Surrey, T. (2012) · Cell · doi:10.1016/j.cell.2012.02.049 · Cited by 382
Mayya, V., Lundgren, D. H., Hwang, S.-I., Rezaul, K., Wu, L., Eng, J. K., Rodionov, V., & Han, D. K. (2009) · Science Signaling · doi:10.1126/scisignal.2000007 · Cited by 372
Multi-resolution contour-based fitting of macromolecular structures
Chacón, P., & Wriggers, W. (2002) · Journal of Molecular Biology · doi:10.1006/jmbi.2002.5438 · Cited by 336
Hawkins, T., Mirigian, M., Selcuk Yasar, M., & Ross, J. L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.005 · Cited by 270
On and Around Microtubules: An Overview
Wade, R. H. (2009) · Molecular Biotechnology · doi:10.1007/s12033-009-9193-5 · Cited by 232
“dimensional microtubule reconstruction obtained by electron cryomicroscopy [ 45 , 57].”
BackgroundMethodSelf-citationMicrotubule-associated proteins control the kinetics of microtubule nucleation
Wieczorek, M., Bechstedt, S., Chaaban, S., & Brouhard, G. J. (2015) · Nature Cell Biology · doi:10.1038/ncb3188 · Cited by 225
LaPointe, N. E., Morfini, G., Brady, S. T., Feinstein, S. C., Wilson, L., & Jordan, M. A. (2013) · NeuroToxicology · doi:10.1016/j.neuro.2013.05.008 · Cited by 219
“Although drugs can induce structural changes in microtubules assembled with GMPCPP (KhrapunovichBaine et al., 2009, 2011), GMPCPP itself has strong effects on microtubule structure (Meurer-Grob et al., 2001; Vale et al., 1994).”
Effects of tubulin acetylation and tubulin acetyltransferase binding on microtubule structure
Howes, S. C., Alushin, G. M., Shida, T., Nachury, M. V., & Nogales, E. (2014) · Molecular Biology of the Cell · doi:10.1091/mbc.e13-07-0387 · Cited by 183
“The pores between protofilaments obtained in this study and previous work (Meurer-Grob et al., 2001; Li et al., 2002) are ∼20 Å in diameter.”
BackgroundTopalidou, I., Keller, C., Kalebic, N., Nguyen, K. C. Q., Somhegyi, H., Politi, K. A., Heppenstall, P., Hall, D. H., & Chalfie, M. (2012) · Current Biology · doi:10.1016/j.cub.2012.03.066 · Cited by 159
McVicker, D. P., Chrin, L. R., & Berger, C. L. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.292987 · Cited by 85
Metadata
- Authors
- Meurer-Grob, P., Kasparian, J., & Wade, R. H.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-06-13
- Volume
- 40
- Issue
- 27
- Pages
- 8000-8008
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W2022288724
- Cited by
- 117
- References
- 1
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.