CoChat

Development and Validation of a Fluorescence Polarization-Based Competitive Peptide-Binding Assay for HLA-A*0201A New Tool for Epitope Discovery

Buchli, Rico, VanGundy, Rodney S., Hickman-Miller, Heather D., Giberson, Christopher F., Bardet, Wilfried, Hildebrand, William H. · 2005 · Biochemistry
Cited by 60

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Various approaches are currently proposed to successfully develop therapies for the prevention and treatment of infectious diseases and cancer. One of the most promising approaches is the development of vaccines that elicit cytotoxic T lymphocyte (CTL) responses. Consequently, identification and exact definition of molecular parameters involved in peptide-MHC class-I interactions of putative CTL epitopes are of prime importance for the development of immunomodulating compounds. To better facilitate epitope discovery, we developed and validated a novel state-of-the-art biochemical HLA-A0201 assay, which is comprised of technologically advanced cutting edge reagents. The technique is based on competition and uses a FITC-labeled reference peptide and highly purified soluble HLA-A0201 molecules to quantitatively measure the binding capacity of nonlabeled peptide candidates. Detection by fluorescence polarization allows real-time measurement of binding ratios without separation steps. During standardization, the problem of assay parameter variation is discussed, showing the dramatic influence of HLA and reference peptide concentrations as well as the choice of the reference peptide itself on IC(50) determinations. For validation, a panel of 15 well-defined HLA-A0201 ligands from various sources covering a broad range of binding affinities was tested. Binding data were used to compare against pre-existing quantitative assay systems. The results obtained demonstrated significant correlation among assay procedures, suggesting that the application of fluorescence polarization in combination with recombinant sHLA molecules is highly advantageous for the accurate assessment of peptide binding. Furthermore, the assay also features high-throughput screening capacity, providing uniquely efficient means of identifying and evaluating immune target molecules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/bi050255v

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 60

Metadata

Authors
Buchli, R., VanGundy, R. S., Hickman-Miller, H. D., Giberson, C. F., Bardet, W., & Hildebrand, W. H.
Venue
Biochemistry
Published
2005-08-26
Volume
44
Issue
37
Pages
12491-12507
ISSN
  • 0006-2960 (ISSN-L)
  • 1520-4995
OpenAlex
W2080303593
Cited by
60
References
1
FWCI
1.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.