Assessment of in Vitro Bioactivity of Hyaluronic Acid and Sulfated Hyaluronic Acid Functionalized Electroactive Polymer
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Electrically conductive polypyrrole (PPY) was surface functionalized with hyaluronic acid (HA) and sulfated hyaluronic acid (SHA) to improve its surface biocompatibility. The immobilization of HA on the PPY film was facilitated by the use of a cross-linker having the appropriate functional groups. The biological activity of the HA functionalized PPY film was assessed by means of an in vitro PC12 cell culture. The cell attachment on different substrates was studied and determined by bicinchoninic acid protein analysis. Cell attachment on the HA functionalized PPY film surface was significantly enhanced in the presence of nerve growth factor. The SHA functionalized PPY film was obtained by the sulfonation of the immobilized HA using pyridinesulfonate. The retention of the biological activity of the immobilized HA after sulfonation was evaluated by the in vitro assessment of the plasma recalcification time (PRT) and platelet adhesion on the substrate. The PRT observed from the SHA functionalized PPY film was significantly prolonged compared with the HA functionalized PPY. Some reduction of platelet adhesion was observed for the SHA functionalized PPY film, compared with that of the HA functionalized PPY film.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wiechelman, K. J., Braun, R. D., & Fitzpatrick, J. D. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90383-1 · Cited by 766
Cited by
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,379
Ghasemi-Mobarakeh, L., Prabhakaran, M. P., Morshed, M., Nasr-Esfahani, M. H., Baharvand, H., Kiani, S., Al-Deyab, S. S., & Ramakrishna, S. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.383 · Cited by 698
Polypyrrole-based conducting polymers and interactions with biological tissues
Ateh, D. D., Navsaria, H. A., & Vadgama, P. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2006.0141 · Cited by 533
Metadata
- Authors
- Cen, L., Neoh, K. G., Li, & Kang, E. T.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-08-24
- Volume
- 5
- Issue
- 6
- Pages
- 2238-2246
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2056424742
- Cited by
- 113
- References
- 1
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.