The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
New Biodegradable Thermogelling Copolymers Having Very Low Gelation Concentrations
Abstract
New biodegradable multiblock amphiphilic and thermosensitive poly(ether ester urethane)s consisting of poly[(R)-3-hydroxybutyrate] (PHB), poly(ethylene glycol) (PEG), and poly(propylene glycol) (PPG) blocks were synthesized, and their aqueous solutions were found to undergo a reversible sol-gel transition upon temperature change at very low copolymer concentrations. The multiblock poly(ether ester urethane)s were synthesized from diols of PHB, PEG, and PPG using 1,6-hexamethylene diisocyanate as a coupling reagent. The chemical structures and molecular characteristics of the copolymers were studied by GPC, 1H NMR, 13C NMR, and FTIR. The thermal stability of the poly(PEG/PPG/PHB urethane)s was studied by thermogravimetry analysis (TGA), and the PHB contents were calculated based on the thermal degradation profile. The results were in good agreement with those obtained from the 1H NMR measurements. The poly(PEG/PPG/ PHB urethane)s presented better thermal stability than the PHB precursors. The water soluble poly(ether ester urethane)s had very low critical micellization concentration (CMC). Aqueous solutions of the new poly(ether ester urethane)s underwent a sol-gel-sol transition as the temperature increased from 4 to 80 degrees C, and showed a very low critical gelation concentration (CGC) ranging from 2 to 5 wt %. As a result of its multiblock architecture, a novel associated micelle packing model can be proposed for the sol-gel transition for the copolymer gels of this system. The new material is thought to be a promising candidate for injectable drug systems that can be formulated at low temperatures and forms a gel depot in situ upon subcutaneous injection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Designing biodegradable multiblock PCL/PLA thermoplastic elastomers
Cohn, D., & Hotovely Salomon, A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.052 · Cited by 355
Cited by
Injectable hydrogels as unique biomedical materials
Yu, L., & Ding, J. (2008) · Chemical Society Reviews · doi:10.1039/b713009k · Cited by 1,545
Thermoresponsive hydrogels in biomedical applications
Klouda, L., & Mikos, A. G. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.02.025 · Cited by 1,349
A mini review on hydrogels classification and recent developments in miscellaneous applications
Varaprasad, K., Raghavendra, G. M., Jayaramudu, T., Yallapu, M. M., & Sadiku, R. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.05.096 · Cited by 534
Water soluble polyhydroxyalkanoates: future materials for therapeutic applications
Li, Z., & Loh, X. J. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00089k · Cited by 291
Self-citationAdvances in biodegradable and injectable hydrogels for biomedical applications
Li, Y., Yang, H. Y., & Lee, D. S. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.12.008 · Cited by 261
Metadata
- Authors
- Loh, X. J., Goh, S. H., & Li, J.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-12-30
- Volume
- 8
- Issue
- 2
- Pages
- 585-593
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2067447097
- Cited by
- 262
- References
- 1
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.