The DOI matches its Crossref record.
Evaluation of the In Vitro Cytotoxicity of Cross-Linked Biomaterials
Open accessAbstract
This study evaluated the in vitro cytotoxicity of poly(propylene fumarate) (PPF). PPF is an aliphatic biodegradable polymer that has been well characterized for use in bone tissue engineering scaffolds. Four different cell types, human mesenchymal stem cells (hMSC), fibroblasts (L929), preosteoblasts (MC3T3), and canine mesenchymal stem cells (cMSC), were used to evaluate the cytotoxicity of PPF. These cell types represent the tissues that PPF would interact with in vivo as a bone tissue scaffold. The sol fraction of the PPF films was measured and then utilized to estimate cross-linking density. Cytotoxicity was evaluated using XTT assay and fluorescence imaging. Results showed that PPF supported similar cell metabolic activities of hMSC, L929, MC3T3, and cMSC compared to the noncytotoxic control, high-density polyethylene (HDPE) and were statistically different than those cultured with the cytotoxic control, a polyurethane film containing 0.1% zinc diethyldithiocarbamate (ZCF). Results showed differing cellular responses to ZCF, the cytotoxic control. The L929 cells had the lowest cell metabolic activity levels after exposure to ZCF compared to the cell metabolic activity levels of the MC3T3, hMSC, or cMSC cells. Qualitative verification of the results using fluorescence imaging demonstrated no change in cell morphology, vacuolization, or detachment when cultured with PPF compared to HDPE or blank media cultures. Overall, the cytotoxicity response of the cells to PPF was demonstrated to be similar to the cytotoxic response of cells to known noncytotoxic materials (HDPE).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical Applications of Biodegradable Polyesters
Manavitehrani, I., Fathi, A., Badr, H., Daly, S., Negahi Shirazi, A., & Dehghani, F. (2016) · Polymers · doi:10.3390/polym8010020 · Cited by 514
Evaluating 3D‐Printed Biomaterials as Scaffolds for Vascularized Bone Tissue Engineering
Wang, M. O., Vorwald, C. E., Dreher, M. L., Mott, E. J., Cheng, M., Cinar, A., Mehdizadeh, H., Somo, S., Dean, D., Brey, E. M., et al. (2015) · Advanced Materials · doi:10.1002/adma.201403943 · Cited by 301
Self-citationCytotoxicity of Gallium–Indium Liquid Metal in an Aqueous Environment
Kim, J.-H., Kim, S., So, J.-H., Kim, K., & Koo, H.-J. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b02320 · Cited by 272
Cai, Z., Wan, Y., Becker, M. L., Long, Y.-Z., & Dean, D. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.03.038 · Cited by 133
Self-citationCornelison, R. C., Wellman, S. M., Park, J. H., Porvasnik, S. L., Song, Y. H., Wachs, R. A., & Schmidt, C. E. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.07.009 · Cited by 64
Levine, A. C., Sparano, A., Twigg, F. F., Numata, K., & Nomura, C. T. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00052 · Cited by 48
Metadata
- Authors
- Wang, M. O., Etheridge, J. M., Thompson, J. A., Vorwald, C. E., Dean, D., & Fisher, J. P.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-04-29
- Volume
- 14
- Issue
- 5
- Pages
- 1321-1329
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W1977611746
- Cited by
- 165
- References
- 0
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.