The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Transparent, Conductive, and Printable Composites Consisting of TEMPO-Oxidized Nanocellulose and Carbon Nanotube
Open accessAbstract
Ultrastrong, transparent, conductive and printable nanocomposites were successfully prepared by mixing single-walled carbon nanotubes (CNTs) with 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO)-oxidized cellulose nanofibrils (TOCNs) with abundant sodium carboxyl groups on the crystalline nanocellulose surfaces. The surface-anionic cellulose nanofibrils had reinforcing and nanodispersing effects on the CNTs both in water used as the dispersed medium and in the dried composite film, providing highly conductive and printable nanocomposites with a small amount of CNTs. TOCNs are therefore expected as an effective flexible matrix that can be used as an alternative to conventional polymers for various electrical materials, when nanocomposited with CNTs and also graphene. Our findings provide a promising route to realize green and flexible electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saito, T., Nishiyama, Y., Putaux, J.-L., Vignon, M., & Isogai, A. (2006) · Biomacromolecules · doi:10.1021/bm060154s · Cited by 1,796
Self-citationTransparent and high gas barrier films of cellulose nanofibers prepared by TEMPO-mediated oxidation
Fukuzumi, H., Saito, T., Iwata, T., Kumamoto, Y., & Isogai, A. (2009) · Biomacromolecules · doi:10.1021/bm801065u · Cited by 1,271
Self-citationElastic modulus of single cellulose microfibrils from tunicate measured by atomic force microscopy
Iwamoto, S., Kai, W., Isogai, A., & Iwata, T. (2009) · Biomacromolecules · doi:10.1021/bm900520n · Cited by 754
Self-citation
Cited by
Use of nanocellulose in printed electronics: a review
Hoeng, F., Denneulin, A., & Bras, J. (2016) · Nanoscale · doi:10.1039/c6nr03054h · Cited by 459
Du, X., Zhang, Z., Liu, W., & Deng, Y. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.04.001 · Cited by 426
Mir, S. H., Nagahara, L. A., Thundat, T., Mokarian-Tabari, P., Furukawa, H., & Khosla, A. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0191808jes · Cited by 386
Hamedi, M. M., Hajian, A., Fall, A. B., Håkansson, K., Salajkova, M., Lundell, F., Wågberg, L., & Berglund, L. A. (2014) · ACS Nano · doi:10.1021/nn4060368 · Cited by 381
Transparent Electronics for Wearable Electronics Application
Won, D., Bang, J., Choi, S. H., Pyun, K. R., Jeong, S., Lee, Y., & Ko, S. H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00139 · Cited by 339
Metadata
- Authors
- Koga, H., Saito, T., Kitaoka, T., Nogi, M., Suganuma, K., & Isogai, A.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-03-04
- Volume
- 14
- Issue
- 4
- Pages
- 1160-1165
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2317887397
- Cited by
- 298
- References
- 3
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.