Dendrimer-Assisted Formation of Fluorescent Nanogels for Drug Delivery and Intracellular Imaging
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Although, in general, nanogels present a good biocompatibility and are able to mimic biological tissues, their unstability and uncontrollable release properties still limit their biomedical applications. In this study, a simple approach was used to develop dual-cross-linked dendrimer/alginate nanogels (AG/G5), using CaCl2 as cross-linker and amine-terminated generation 5 dendrimer (G5) as a cocrosslinker, through an emulsion method. Via their strong electrostatic interactions with anionic AG, together with cross-linker Ca(2+), G5 dendrimers can be used to mediate the formation of more compact structural nanogels with smaller size (433 ± 17 nm) than that (873 ± 116 nm) of the Ca(2+)-cross-linked AG nanogels in the absence of G5. Under physiological (pH 7.4) and acidic (pH 5.5) conditions, the sizes of Ca(2+)-cross-linked AG nanogels gradually decrease probably because of their degradation, while dual-cross-linked AG/G5 nanogels maintain a relatively more stable structure. Furthermore, the AG/G5 nanogels effectively encapsulate the anticancer drug doxorubicin (Dox) with a loading capacity 3 times higher than that of AG nanogels. The AG/G5 nanogels were able to release Dox in a sustained way, avoiding the burst release observed for AG nanogels. In vitro studies show that the AG/G5-Dox NGs were effectively taken up by CAL-72 cells (a human osteosarcoma cell line) and maintain the anticancer cytotoxicity levels of free Dox. Interestingly, G5 labeled with a fluorescent marker can be integrated into the nanogels and be used to track the nanogels inside cells by fluorescence microscopy. These findings demonstrate that AG/G5 nanogels may serve as a general platform for therapeutic delivery and/or cell imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oliveira, J. M., Salgado, A. J., Sousa, N., Mano, J. F., & Reis, R. L. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.006 · Cited by 182
Cited by
An overview of nanoparticles commonly used in fluorescent bioimaging
Wolfbeis, O. S. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00392f · Cited by 1,631
Soft fluorescent nanomaterials for biological and biomedical imaging
Peng, H.-S., & Chiu, D. T. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00294f · Cited by 407
Tomalia, D. A., Klajnert-Maculewicz, B., Johnson, K. A.-M., Brinkman, H. F., Janaszewska, A., & Hedstrand, D. M. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.09.004 · Cited by 395
Managing the immune microenvironment of osteosarcoma: the outlook for osteosarcoma treatment
Tian, H., Cao, J., Li, B., Nice, E. C., Mao, H., Zhang, Y., & Huang, C. (2023) · Bone Research · doi:10.1038/s41413-023-00246-z · Cited by 232
Dendrimers in combination with natural products and analogues as anti-cancer agents
Mignani, S., Rodrigues, J., Tomas, H., Zablocka, M., Shi, X., Caminade, A.-M., & Majoral, J.-P. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00550d · Cited by 219
Self-citation
Metadata
- Authors
- Gonçalves, M., Maciel, D., Capelo, D., Xiao, S., Sun, W., Shi, X., Rodrigues, J., Tomás, H., & Li, Y.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-01-28
- Volume
- 15
- Issue
- 2
- Pages
- 492-499
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2316216564
- Cited by
- 85
- References
- 1
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.