CoChat

Chondroitin Sulfate Coatings Display Low Platelet but High Endothelial Cell Adhesive Properties Favorable for Vascular Implants

Thalla, Pradeep K., Fadlallah, Hicham, Liberelle, Benoit, Lequoy, Pauline, De Crescenzo, Gregory, Merhi, Yahye, Lerouge, Sophie · 2014 · Biomacromolecules
Cited by 74

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This study highlights the advantages of chondroitin sulfate (CS) as a sublayer combining selective low-fouling properties, low-platelet adhesion and pro-adhesive properties on endothelial cells, making CS promising for vascular graft applications. These properties were evaluated by comparing CS with well-known low-fouling coatings such as poly(ethylene glycol) (PEG) and carboxymethylated dextran (CMD), which were covalently grafted on primary amine-rich plasma polymerized (LP) films. Protein adsorption studies by quartz crystal microbalance with dissipation monitoring (QCM-D) and fluorescence measurements showed that CS is as effective as PEG in reducing fibrinogen adsorption (~90% reduction). CS also largely reduced adsorption of bovine serum albumin (BSA) as well as fetal bovine serum (FBS) but to a lower extent than PEG and CMD surfaces (72% vs 85% for BSA and 66% vs 89% for FBS). Whole blood perfusion assays indicated that, while LP surfaces were highly reactive with platelets, PEG, CMD, and CS grafted surfaces drastically decreased platelet adhesion and activation to levels significantly lower than polyethylene terephthalate (PET) surfaces. Finally, while human umbilical vein endothelial cell (HUVEC) adhesion and growth were found to be very limited on PEG and CMD, they were significantly increased on CS compared to that on bare PET and reached similar values as those for tissue culture polystyrene positive controls. Interestingly, HUVEC retention during perfusion with blood was found to be excellent on CS but poor on PET. Overall, our results suggest that the CS surface has the advantage of promoting HUVEC growth and resistance to flow-induced shear stress while preventing fibrinogen and platelet attachment. Such a nonthrombogenic but endothelial-cell adhesive surface is thus promising to limit vascular graft occlusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/bm5003762

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

Metadata

Authors
Thalla, P. K., Fadlallah, H., Liberelle, B., Lequoy, P., De Crescenzo, G., Merhi, Y., & Lerouge, S.
Venue
Biomacromolecules
Published
2014-06-25
Volume
15
Issue
7
Pages
2512-2520
ISSN
  • 1525-7797 (ISSN-L)
  • 1526-4602
OpenAlex
W2019265265
Cited by
74
References
1
FWCI
3.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.