Biocompatibility of HEMA Copolymers Designed for Treatment of CNS Diseases with Polymer-Encapsulated Cells
Open accessThe DOI matches its Crossref record.
Abstract
Surrounding the cells with a semipermeable polymeric membrane allows transplanting unmatched xenogeneic cells without a risk of their rejection. We prepared and tested several 2-hydroxyethyl methacrylate (HEMA) copolymers with alkyl methacrylates or acrylates to find out which was the most valuable for cell encapsulation. On the basis of optimum physical properties and good results of cytotoxicity tests, HEMA-EMA copolymer was chosen as a suitable candidate for encapsulation and immunoprotection of xenogeneic cells before their grafting into the central nervous system (CNS). To characterize the biocompatibility of p(HEMA-co-EMA) copolymer in the CNS, we implanted microcapsules made of this hydrogel into the brains of adult rats that were allowed to survive for 0.5, 1, 3, 6, and 9 months. Analysis of histological sections containing the implantation site was aimed at assessment of the cellular density at the implant-brain interface and identification of cell types participating in a tissue reaction. Our results indicated that the tissue reaction that was observed was caused largely by the implantation procedure because HLA-DR- and GSI-B4-positive macrophages/microglia infiltrated mainly the implantation channel. The number of these cells declined with time, which was true also for GFAP-positive reactive astrocytes, as well as for foreign body giant cells. The amount of connective tissue components surrounding the implanted microcapsules increased only slightly. These findings indicated that p(HEMA-co-EMA) hydrogel was well tolerated after implantation in the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
“…is complete, and perhaps as long as the material remains in contact with brain tissue (Stensaas and Stensaas, 1976, 1978; Winn t al., 1989; Edell et al., 1992; Menei et al., 1994; Kunkler and Kraig, 1997; Mofid et al., 1997; Emerich et al., 1999; Mokry et al., 2000; Szarowski et al., 2003).”
BackgroundBrain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Repairing injured peripheral nerves: Bridging the gap
Deumens, R., Bozkurt, A., Meek, M. F., Marcus, M. A. E., Joosten, E. A. J., Weis, J., & Brook, G. A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.002 · Cited by 510
Current applications and future perspectives of artificial nerve conduits
Jiang, X., Lim, S. H., Mao, H.-Q., & Chew, S. Y. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2009.09.009 · Cited by 394
Biocompatibility of implantable synthetic polymeric drug carriers: focus on brain biocompatibility
Fournier, E., Passirani, C., Montero-Menei, C. N., & Benoit, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00161-3 · Cited by 353
Metadata
- Authors
- Mokry, J., Karbanova, J., Lukas, J., Paleckova, V., & Dvorankova, B.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2000-10-06
- Volume
- 16
- Issue
- 5
- Pages
- 897-904
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W2141019852
- Cited by
- 38
- References
- 0
- FWCI
- 0.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility of HEMA Copolymers Designed for Treatment of CNS Diseases with Polymer-Encapsulated Cells. https://app.cochat.ai/papers/10.1021/bp000113m
- The paper
- Mokry, J., Karbanova, J., Lukas, J., Paleckova, V., & Dvorankova, B. (2000). Biocompatibility of HEMA Copolymers Designed for Treatment of CNS Diseases with Polymer-Encapsulated Cells. Biotechnology Progress. https://doi.org/10.1021/bp000113m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.