Kinetics of Hepatocyte Spheroid Formation
The DOI matches its Crossref record.
Abstract
Cultured hepatocytes have been explored for use in a bioartificial liver. Spheroids formed by cultured hepatocytes exhibit enhanced liver‐specific functions. The kinetics of spheroid formation, using rat hepatocytes, was studied on positively charged surfaces that were either uncoated or coated with collagen or (hydroxyethyl)methacrylate (HEMA). Optimal spheroid formation was obtained on positively charged (Primaria) surfaces at inoculum densities in the range of (3–9) × 10 4 cells/cm 2. Cells initially attached and spread out on the surface. Subsequent retraction led to the emergence of small clumps of cells attached to the surface, from which spheroids formed and shed off into suspension. The process of spheroid formation took more than 72 h and was accompanied by a decrease in the surface area occupied by attached cells. Optical sectioning of fluorescently stained spheroids using confocal microscopy indicated that most of the cells in the spheroid were viable. Spheroids also maintained a constant albumin synthesis rate for over 7 days in culture. Spheroid formation was evaluated in terms of the changes in spheroid diameter, the surface area covered by attached cells, and the total protein content of the fraction of cells that formed spheroids. The quantitative methodologies developed were used to assess the effect of inoculum cell concentration on spheroid formation and to evaluate the kinetics of spheroid formation on different surfaces both favorable and nonfavorable to spheroid formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schwartz, R. E., Reyes, M., Koodie, L., Jiang, Y., Blackstad, M., Lund, T., Lenvik, T., Johnson, S., Hu, W.-S., & Verfaillie, C. M. (2002) · Journal of Clinical Investigation · doi:10.1172/jci0215182 · Cited by 863
Self-citationHepatocyte behavior within three-dimensional porous alginate scaffolds
Glicklis, R., Shapiro, L., Agbaria, R., Merchuk, J. C., & Cohen, S. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(20000205)67:3<344::aid-bit11>3.0.co;2-2 · Cited by 391
Functional behavior of primary rat liver cells in a three-dimensional perfused microarray bioreactor
Powers, M. J., Janigian, D. M., Wack, K. E., Baker, C. S., Stolz, D. B., & Griffith, L. G. (2002) · Tissue Engineering · doi:10.1089/107632702760184745 · Cited by 234
Costa, E. C., de Melo‐Diogo, D., Moreira, A. F., Carvalho, M. P., & Correia, I. J. (2018) · Biotechnology Journal · doi:10.1002/biot.201700417 · Cited by 224
Three-dimensional co-culture of hepatocytes and stellate cells
Abu-Absi, S. F., Hansen, L. K., & Hu, W.-S. (2004) · Cytotechnology · doi:10.1007/s10616-004-7996-6 · Cited by 92
Self-citation
Metadata
- Authors
- Peshwa, M. V., Wu, F. J., Follstad, B. D., Cerra, F. B., & Hu, W.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 10
- Issue
- 5
- Pages
- 460-466
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W2050956753
- Cited by
- 67
- References
- 0
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinetics of Hepatocyte Spheroid Formation. https://app.cochat.ai/papers/10.1021/bp00029a002
- The paper
- Peshwa, M. V., Wu, F. J., Follstad, B. D., Cerra, F. B., & Hu, W. (1994). Kinetics of Hepatocyte Spheroid Formation. Biotechnology Progress. https://doi.org/10.1021/bp00029a002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.