Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 170

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Internal and External Mass Transfer in Biofilms Grown at Various Flow Velocities

Beyenal, Haluk, Lewandowski, Zbigniew · 2002 · Biotechnology Progress

Abstract

It appears that biofilms arrange their internal structure according to the flow velocity at which they are grown, which affects the internal mass transfer rate and microbial activity. In biofilms grown at various flow velocities we determined the vertical profiles of the local relative effective diffusivity (termed D l ) at several locations within each biofilm. From these profiles we calculated the surface‐averaged relative effective diffusivity (termed D sa ) at various distances from the bottom and plotted it against these distances. The D sa decreased linearly toward the bottom, forming well‐defined profiles that were different for each biofilm. The gradients of these profiles were multiplied by the diffusivity of oxygen, ζ = D w d D sa /d z , and plotted versus the flow velocity at which each biofilm was grown. The gradients were low at flow velocities below 10 cm/s, reached a maximum at a flow velocity of 10 cm/s, and decreased again at flow velocities exceeding 10 cm/s. The existence of a maximum indicates a possibility that two opposing forces were affecting the slope of the profiles. To explain these observations we hypothesized that biofilms, depending on the flow velocity at which they are grown, arrange their internal architecture to control (1) the nutrient transport rate and (2) the mechanical pliability needed to resist the shear stress of the water flowing past them. It appears that biofilms attempt to satisfy the second goal first, to increase their mechanical strength, and that they do so at the expense of the nutrient transfer rate to deeper layers. This strength increase is associated with an increase in biofilm density, which slows down the internal mass transport rate. Biofilms grown at low flow velocities exhibit low density and high effective diffusivity but cannot resist higher shear stress, whereas biofilms grown at higher flow velocities are denser and can resist higher shear stress but have a lower effective diffusivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/bp010129s

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Beyenal, H., & Lewandowski, Z.
Venue
Biotechnology Progress
Publisher
Wiley
Published
2002-01
Volume
18
Issue
1
Pages
55-61
ISSN
  • 1520-6033 (ISSN-L)
  • 8756-7938
OpenAlex
W2020427340
Cited by
170
References
1
FWCI
2.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.