The DOI matches its Crossref record.
Dual Excitation Ratiometric Fluorescent pH Sensor for Noninvasive Bioprocess Monitoring: Development and Application
Abstract
The development and application of a fluorescent excitation‐ratiometric, noninvasive pH sensor for continuous on‐line fermentation monitoring is presented. The ratiometric approach is robust and insensitive to factors such as source intensity, photobleaching, or orientation of the patch, and since measurements can be made with external instrumentation and without direct contact with the patch, detection is completely noninvasive. The fluorescent dye 8‐hydroxy‐1,3,6‐pyrene trisulfonic acid was immobilized onto Dowex strongly basic anion‐exchange resin, which was subsequently entrapped into a proton‐permeable hydrogel layer. The sensor layer was polymerized directly onto a white microfiltration membrane backing that provided an optical barrier to the fluorescence and scatter of the fermentation medium. The ratio of emission intensity at 515 nm excited at 468 nm to that excited at 408 nm correlated well with the pH of clear buffers, over the pH range of 6–9. The sensor responded rapidly (<9 min) and reversibly to changes in the solution pH with high precision. The sterilizable HPTS sensor was used for on‐line pH monitoring of an E. coli fermentation. The output from the indwelling sensor patch was always in good agreement with the pH recorded off‐line with an ISFET probe, with a maximum discrepancy of 0.05 pH units. The sensor is easily adaptable to closed‐loop feedback control systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Yu, F., Li, P., Li, G., Zhao, G., Chu, T., & Han, K. (2011) · Journal of the American Chemical Society · doi:10.1021/ja202582x · Cited by 578
Wencel, D., Abel, T., & McDonagh, C. (2014) · Analytical Chemistry · doi:10.1021/ac4035168 · Cited by 541
Materials for fluorescence-based optical chemical sensors
Wolfbeis, O. S. (2005) · Journal of Materials Chemistry · doi:10.1039/b501536g · Cited by 486
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Metadata
- Authors
- Kermis, H. R., Kostov, Y., Harms, P., & Rao, G.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 18
- Issue
- 5
- Pages
- 1047-1053
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W2151036986
- Cited by
- 162
- References
- 0
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual Excitation Ratiometric Fluorescent pH Sensor for Noninvasive Bioprocess Monitoring: Development and Application. https://app.cochat.ai/papers/10.1021/bp0255560
- The paper
- Kermis, H. R., Kostov, Y., Harms, P., & Rao, G. (2002). Dual Excitation Ratiometric Fluorescent pH Sensor for Noninvasive Bioprocess Monitoring: Development and Application. Biotechnology Progress. https://doi.org/10.1021/bp0255560
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.