The DOI matches its Crossref record.
Fine Affinity Discrimination by Yeast Surface Display and Flow Cytometry
Abstract
Yeast surface display is a eucaryotic system for the directed evolution of protein binding and stability. For antibody affinity maturation, achievable single‐pass enrichment factors are a critical variable. Both reliable recovery of rare clones (yield) and effective differentiation between clones of only slightly improved affinity (purity) are paramount. To validate yeast display's purification potential, trial sorting experiments were performed. The D1.3 (anti‐hen egg lysozyme) single chain variable fragment antibody and a 2‐fold higher affinity mutant (M3) were each displayed on the surface of Saccharomyces cerevisiae. M3‐displaying cells were mixed into the D1.3‐displaying cells at a ratio of 1:1000. Cells were fluorescently labeled according to antigen equilibrium binding and then sorted using a flow cytometer. Single‐pass enrichment of M3‐displaying cells was 125‐fold (± 65‐fold). This level of performance is achievable because of the precision and reproducibility of optimal labeling conditions. This work further demonstrates the capability of yeast display for very fine discrimination between mutant clones of similar affinity. Because large improvements in affinity typically result from combinations of small changes, this capability to identify subtle improvements is essential for rapid affinity maturation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Selecting and screening recombinant antibody libraries
Hoogenboom, H. R. (2005) · Nature Biotechnology · doi:10.1038/nbt1126 · Cited by 973
Isolating and engineering human antibodies using yeast surface display
Chao, G., Lau, W. L., Hackel, B. J., Sazinsky, S. L., Lippow, S. M., & Wittrup, K. D. (2006) · Nature Protocols · doi:10.1038/nprot.2006.94 · Cited by 909
Self-citationDirected evolution of antibody fragments with monovalent femtomolar antigen-binding affinity
Boder, E. T., Midelfort, K. S., & Wittrup, K. D. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170297297 · Cited by 673
Self-citationFeldhaus, M. J., Siegel, R. W., Opresko, L. K., Coleman, J. R., Feldhaus, J. M. W., Yeung, Y. A., Cochran, J. R., Heinzelman, P., Colby, D., Swers, J., et al. (2003) · Nature Biotechnology · doi:10.1038/nbt785 · Cited by 520
Self-citationMeasuring the sequence-affinity landscape of antibodies with massively parallel titration curves
Adams, R. M., Mora, T., Walczak, A. M., & Kinney, J. B. (2016) · eLife · doi:10.7554/elife.23156 · Cited by 137
Metadata
- Authors
- Van Antwerp, J. J., & Wittrup, K. D.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2000-01
- Volume
- 16
- Issue
- 1
- Pages
- 31-37
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W1584021532
- Cited by
- 168
- References
- 0
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fine Affinity Discrimination by Yeast Surface Display and Flow Cytometry. https://app.cochat.ai/papers/10.1021/bp990133s
- The paper
- Van Antwerp, J. J., & Wittrup, K. D. (2000). Fine Affinity Discrimination by Yeast Surface Display and Flow Cytometry. Biotechnology Progress. https://doi.org/10.1021/bp990133s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.