The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Comparison of Topological, Shape, and Docking Methods in Virtual Screening
Abstract
Virtual screening benchmarking studies were carried out on 11 targets to evaluate the performance of three commonly used approaches: 2D ligand similarity (Daylight, TOPOSIM), 3D ligand similarity (SQW, ROCS), and protein structure-based docking (FLOG, FRED, Glide). Active and decoy compound sets were assembled from both the MDDR and the Merck compound databases. Averaged over multiple targets, ligand-based methods outperformed docking algorithms. This was true for 3D ligand-based methods only when chemical typing was included. Using mean enrichment factor as a performance metric, Glide appears to be the best docking method among the three with FRED a close second. Results for all virtual screening methods are database dependent and can vary greatly for particular targets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Friesner, R. A., Banks, J. L., Murphy, R. B., Halgren, T. A., Klicic, J. J., Mainz, D. T., Repasky, M. P., Knoll, E. H., Shelley, M., Perry, J. K., et al. (2004) · Journal of Medicinal Chemistry · doi:10.1021/jm0306430 · Cited by 10,057
Benchmarking sets for molecular docking.
Huang, N., Shoichet, B. K., & Irwin, J. J. (2006) · Journal of Medicinal Chemistry · doi:10.1021/jm0608356 · Cited by 1,318
Do Structurally Similar Molecules Have Similar Biological Activity?
Martin, Y. C., Kofron, J. L., & Traphagen, L. M. (2002) · Journal of Medicinal Chemistry · doi:10.1021/jm020155c · Cited by 806
Comparative evaluation of eight docking tools for docking and virtual screening accuracy
Kellenberger, E., Rodrigo, J., Muller, P., & Rognan, D. (2004) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.20149 · Cited by 577
Why do we need so many chemical similarity search methods?
Sheridan, R. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02411-x · Cited by 412
Self-citation
Cited by
Chen, Y.-C. (2015) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2014.12.001 · Cited by 611
Exploiting machine learning for end-to-end drug discovery and development
Ekins, S., Puhl, A. C., Zorn, K. M., Lane, T. R., Russo, D. P., Klein, J. J., Hickey, A. J., & Clark, A. M. (2019) · Nature Materials · doi:10.1038/s41563-019-0338-z · Cited by 578
Moitessier, N., Englebienne, P., Lee, D., Lawandi, J., & Corbeil, C. R. (2008) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0707515 · Cited by 514
Recognizing Pitfalls in Virtual Screening: A Critical Review
Scior, T., Bender, A., Tresadern, G., Medina-Franco, J. L., Martínez-Mayorga, K., Langer, T., Cuanalo-Contreras, K., & Agrafiotis, D. K. (2012) · Journal of Chemical Information and Modeling · doi:10.1021/ci200528d · Cited by 438
Sastry, M., Lowrie, J. F., Dixon, S. L., & Sherman, W. (2010) · Journal of Chemical Information and Modeling · doi:10.1021/ci100062n · Cited by 332
Metadata
- Authors
- McGaughey, G. B., Sheridan, R. P., Bayly, C. I., Culberson, J. C., Kreatsoulas, C., Lindsley, S., Maiorov, V., Truchon, J.-F., & Cornell, W. D.
- Venue
- Journal of Chemical Information and Modeling
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-06-26
- Volume
- 47
- Issue
- 4
- Pages
- 1504-1519
- ISSN
- 1549-9596 (ISSN-L)
- 1549-960X
- OpenAlex
- W2125792789
- Cited by
- 417
- References
- 5
- FWCI
- 35.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Topological, Shape, and Docking Methods in Virtual Screening. https://app.cochat.ai/papers/10.1021/ci700052x
- The paper
- McGaughey, G. B., Sheridan, R. P., Bayly, C. I., Culberson, J. C., Kreatsoulas, C., Lindsley, S., Maiorov, V., Truchon, J.-F., & Cornell, W. D. (2007). Comparison of Topological, Shape, and Docking Methods in Virtual Screening. Journal of Chemical Information and Modeling. https://doi.org/10.1021/ci700052x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.