The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ultrasonic Irradiation: A Novel Approach To Prepare Conductive Polyaniline/Nanocrystalline Titanium Oxide Composites
Abstract
A novel approach, i.e., ultrasonic irradiation, was used to prepare polyaniline/nanocrystalline TiO 2 composite particles. Polymerization of aniline proceeded under ultrasonic irradiation in the presence of nanocrystalline TiO 2 . The aggregation of nano TiO 2 can be reduced under ultrasonic irradiation, and the nanoparticles can be redispersed in the aqueous solution. The polyaniline deposits on the surface of the nanoparticle, which leads to a core−shell structure. The resulting polyaniline/nano TiO 2 composite particles are spherical, and the sizes vary with the content of TiO 2 . The polyaniline/nano TiO 2 composite particles prepared by the conventional stirring method have a “raspberry” aggregate structure, which is different from that obtained through ultrasonic irradiation. The presence of nanocrystalline TiO 2 strengthens the UV absorption of polyaniline and leads to a blue shift of the π-polaron absorption of polyaniline. Ultrasound can enhance the doping level. When polyaniline deposits on the surface of nano TiO 2, the crystalline behavior of polyaniline is hampered and the degree of crystallinity decreases. With increased TiO 2 content, the H-bonding interaction is strengthened and the characteristic peaks of benzoid and quinoid are shifted. X-ray photoelectron spectroscopy (XPS) shows that the ratio of the number of Ti and N atoms (Ti/N) on the surface is lower than that in the bulk. This is strong evidence for a polyaniline-encapsulated nano TiO 2 structure. The conductivity of the composites obtained through ultrasonic irradiation decreases with increasing TiO 2 content. Ultrasonic irradiation contributes to the increase in the conductivity compared with conventional stirring. When the content of polyaniline decreases to ∼10%, the conductivity of composite still remains at 10 - 1 S·cm - 1 . Ultrasonic irradiation provides us a new way to prepare 0−3-dimensional conducting polymer/nanocrystalline particle composites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-cost, high-efficiency solar cell based on dye-sensitized colloidal TiO2 films
O'Regan, B., & Grätzel, M. (1991) · Nature · doi:10.1038/353737a0 · Cited by 28,599
Cited by
Feng, X., Mao, C., Yang, G., Hou, W., & Zhu, J.-J. (2006) · Langmuir · doi:10.1021/la053403r · Cited by 351
Kannusamy, P., & Sivalingam, T. (2013) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2013.03.015 · Cited by 146
Metadata
- Authors
- Xia, H., & Wang, Q.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-04-18
- Volume
- 14
- Issue
- 5
- Pages
- 2158-2165
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W2084438377
- Cited by
- 475
- References
- 1
- FWCI
- 16.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonic Irradiation: A Novel Approach To Prepare Conductive Polyaniline/Nanocrystalline Titanium Oxide Composites. https://app.cochat.ai/papers/10.1021/cm0109591
- The paper
- Xia, H., & Wang, Q. (2002). Ultrasonic Irradiation: A Novel Approach To Prepare Conductive Polyaniline/Nanocrystalline Titanium Oxide Composites. Chemistry of Materials. https://doi.org/10.1021/cm0109591
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.