Probing the Local Structure and the Role of Protons in Lithium Sorption Processes of a New Lithium-Rich Manganese Oxide
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Lithium exchange mechanisms, local structure, and its possible evolutions on lithium extraction and reinsertion are studied in Li 1.6 Mn 1.6 O 4, a new lithium-rich manganese oxide showing improved lithium sorption. The parent Li 1.6 Mn 1.6 O 4 and its lithium-extracted and lithium-reinserted forms are characterized by X-ray absorption (EXAFS and XANES) and incoherent inelastic neutron scattering (IINS) spectroscopies. Lattice hydroxyl groups are detected in the lithium-extracted sample; the chemical reinsertion of lithium removes most of the hydroxyl groups, but some protons remain in the structure mainly as structural water. X-ray absorption spectroscopy at the manganese K-edge indicates a local spinel structure of Li 1.6 Mn 1.6 O 4 with manganese in oxidation state 4+. The structural arrangement and Mn oxidation state remain unchanged when lithium is extracted and reinserted. The lithium sorption occurs by Li + /H + ion exchange process, as for Li 1.33 Mn 1.67 O 4, the previously considered end member of the Li 1+ x Mn 2 - x O 4 spinel lithium-rich series. Since the cation-to-anion ratio of Li 1.6 Mn 1.6 O 4 is not that which is typical for a spinel, the new lithium-rich manganese oxide has a spinel structure with the extra Li + probably in interstitial sites, although lithium cannot be located unequivocally from these results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chitrakar, R., Kanoh, H., Miyai, Y., & Ooi, K. (2001) · Industrial & Engineering Chemistry Research · doi:10.1021/ie000911h · Cited by 340
Self-citation
Cited by
Extraction of lithium with functionalized lithium ion-sieves
Xu, X., Chen, Y., Wan, P., Gasem, K., Wang, K., He, T., Adidharma, H., & Fan, M. (2016) · Progress in Materials Science · doi:10.1016/j.pmatsci.2016.09.004 · Cited by 536
“The X-ray absorption spectroscopy of Li 1.6 Mn 1.6 O 4 samples by Ariza et al. [74] showed that no overall shift of the manganese absorption edge after lithium extraction/reinsertion.”
BackgroundInfluentialLithium recovery from salt lake brine by H 2 TiO 3
Chitrakar, R., Makita, Y., Ooi, K., & Sonoda, A. (2014) · Dalton Trans. · doi:10.1039/c4dt00467a · Cited by 345
Self-citationIntroduction of manganese-based lithium-ion Sieve-A review
Weng, D., Duan, H., Hou, Y., Huo, J., Chen, L., Zhang, F., & Wang, J. (2020) · Progress in Natural Science: Materials International · doi:10.1016/j.pnsc.2020.01.017 · Cited by 230
Study on Li+ uptake by lithium ion-sieve via the pH technique
Wang, L., Meng, C. G., & Ma, W. (2009) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2008.09.050 · Cited by 121
Reich, R., Slunitschek, K., Danisi, R. M., Eiche, E., & Kolb, J. (2023) · Mineral Processing and Extractive Metallurgy Review · doi:10.1080/08827508.2022.2047041 · Cited by 120
Metadata
- Authors
- Ariza, M. J., Jones, D. J., Rozière, J., Chitrakar, R., & Ooi, K.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-02-15
- Volume
- 18
- Issue
- 7
- Pages
- 1885-1890
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W1983590142
- Cited by
- 43
- References
- 1
- FWCI
- 0.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.