Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Structure and Dynamics for LiBH4−LiCl Solid Solutions

Open access
Arnbjerg, Lene M., Ravnsbæk, Dorthe B., Filinchuk, Yaroslav, Vang, Ronnie T., Cerenius, Yngve, Besenbacher, Flemming, Jørgensen, Jens-Erik, Jakobsen, Hans Jørgen, Jensen, Torben R.·2009·Chemistry of Materials

Abstract

High Resolution Image Download MS PowerPoint Slide A surprisingly high degree of structural and compositional dynamics is observed in the system LiBH 4 −LiCl as a function of temperature and time. Rietveld refinement of synchrotron radiation powder X-ray diffraction (SR-PXD) data reveals that Cl − readily substitutes for BH 4 − in the structure of LiBH 4 . Prolonged heating a sample of LiBH 4 −LiCl (1:1 molar ratio) above the phase transition temperature and below the melting point (108 < T < 275 °C) can produce highly chloride substituted hexagonal lithium borohydride, h -Li(BH 4 ) 1− x Cl x, e.g., x ∼ 0.42, after heating from room temperature (RT) to 224 °C at 2.5 °C/min. LiCl has a higher solubility in h -LiBH 4 as compared to orthorhombic lithium borohydride, o -LiBH 4, which is illustrated by a LiBH 4 −LiCl (1:1) sample equilibrated at 245 °C for 24 days and left at RT for another 13 months. Rietveld refinement reveals that this sample contains o -Li(BH 4 ) 0.91 Cl 0.09 and LiCl. This illustrates a significantly faster dissolution of LiCl in h -LiBH 4 as compared to a slower segregation of LiCl from o -LiBH 4, which is also demonstrated by in situ SR-PXD from three cycles of heating and cooling of the same Li(BH 4 ) 0.91 Cl 0.09 sample. The substitution of the smaller Cl − for the larger BH 4 − ion is clearly observed as a reduction in the unit cell volume as a function of time and temperature. A significant stabilization of h -LiBH 4 is found to depend on the degree of anion substitution. Variable temperature solid-state magic-angle spinning (MAS) 7 Li and 11 B NMR experiments on pure LiBH 4 show an increase in full width at half maximum (fwhm) when approaching the phase transition from o - to h -LiBH 4, which indicates an increase of the relaxation rate (i.e., T 2 decreases). A less pronounced effect is observed for ion-substituted Li(BH 4 ) 1− x Cl x, 0.09 < x < 0.42. The MAS NMR experiments also demonstrate a higher degree of motion in the hexagonal phase, i.e., fwhm is reduced by more than a factor of 10 at the o - to h -LiBH 4 phase transition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/cm902013k

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 158

Metadata

Authors
Arnbjerg, L. M., Ravnsbæk, D. B., Filinchuk, Y., Vang, R. T., Cerenius, Y., Besenbacher, F., Jørgensen, J.-E., Jakobsen, H. J., & Jensen, T. R.
Venue
Chemistry of Materials
Published
2009-11-18
Volume
21
Issue
24
Pages
5772-5782
ISSN
  • 0897-4756 (ISSN-L)
  • 1520-5002
OpenAlex
W2131089536
Cited by
158
References
1
FWCI
9.09
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.