The DOI matches its Crossref record.
Highly Active Two-Photon Dyes: Design, Synthesis, and Characterization toward Application
Abstract
A series of compounds with systematically varied molecular structures which exhibit very large effective two-photon cross sections has been synthesized and characterized in solution using a nonlinear transmission technique. The general structure of these compounds can be categorized into two basic structural families: acceptor/donor/donor/acceptor and donor/bridge/acceptor. This study attempts to determine certain molecular structure/effective two-photon absorption relationships by careful characterization and as a function of systematically varied changes in the organic structure of the dye molecules. Such information can be useful in the design of more efficient two-photon dyes for imaging and power-limiting applications. The results of the study indicate that with the incorporation of certain combinations of structural elements, dyes can be synthesized which have greatly increased effective cross sections as high as 152.5 × 10 - 48 cm 4 s/photon molecule in benzene solution at 800 nm using 8 ns pulses. This value is orders of magnitude higher than commercially available organic dyes measured at the same wavelength. Although the process is thought to involve a combination of two-photon absorption and excited state absorption phenomena, the information gathered from these new families of dyes has provided an important first step in producing improved materials for use in many different two-photon technology application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ovsianikov, A., Mironov, V., Stampfl, J., & Liska, R. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.48 · Cited by 160
Metadata
- Authors
- Reinhardt, B. A., Brott, L. L., Clarson, S. J., Dillard, A. G., Bhatt, J. C., Kannan, R., Yuan, L., He, G. S., & Prasad, P. N.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-07-01
- Volume
- 10
- Issue
- 7
- Pages
- 1863-1874
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W2019649880
- Cited by
- 728
- References
- 0
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.