Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record.

Accurate Method for Calculating Mesopore Size Distributions from Argon Adsorption Data at 87 K Developed Using Model MCM-41 Materials

Kruk, Michal, Jaroniec, Mietek·2000·Chemistry of Materials

Abstract

Argon adsorption isotherms were measured at 87 K for two macroporous silicas and a series of high-quality MCM-41 silicas with approximately cylindrical pores of average diameters from 2 to 6.5 nm. The pore sizes of the MCM-41 samples were accurately determined in earlier studies on the basis of powder X-ray diffraction and nitrogen adsorption using a geometrical relation between the pore volume, pore−center distance, and pore size in the honeycomb structure. Thus acquired model argon adsorption data for cylindrical mesopores were used to determine the statistical film thickness in the pores and the relation between the pore core radius and the capillary condensation/evaporation pressure. The statistical film thickness curve ( t -curve) was extrapolated over the entire pressure range by using data for suitable macroporous silicas. The t -curve is reported in forms of a simple empirical equation and tabulated data. The relation between the pore core radius and the capillary condensation pressure was interpolated and extrapolated over the range from about 2 to at least 50 nm using a suitable empirical equation, which is approximately equivalent to the Kelvin equation for large mesopore sizes. These relations were used in a standard procedure to calculate mesopore size distributions (PSDs). The obtained pore sizes were in excellent agreement with those evaluated on the basis of the geometrical method using X-ray diffraction (XRD) and primary mesopore volume data. Moreover, positions, heights, and widths of the PSD peaks in the primary mesopore range calculated from argon data were in remarkable agreement with those of the PSD data calculated from nitrogen adsorption data at 77 K using a properly calibrated method reported recently. The agreement extended also on the secondary mesopore range (above about 10 nm). The method also correctly reproduced MCM-41 total pore volumes obtained using a single-point method. Thus, an accurate and self-consistent method for calculating PSDs for silicas with cylindrical pores from argon adsorption data measured at 87 K was successfully developed. Moreover, the reported data for macroporous silicas can be used in comparative plot analysis to determine the external surface areas, primary mesopore volumes, and micropore volumes of microporous and mesoporous silicas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/cm9905601

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 172

Metadata

Authors
Kruk, M., & Jaroniec, M.
Venue
Chemistry of Materials
Published
1999-12-11
Volume
12
Issue
1
Pages
222-230
ISSN
  • 0897-4756 (ISSN-L)
  • 1520-5002
OpenAlex
W2071801117
Cited by
172
References
0
FWCI
7.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accurate Method for Calculating Mesopore Size Distributions from Argon Adsorption Data at 87 K Developed Using Model MCM-41 Materials. https://app.cochat.ai/papers/10.1021/cm9905601
The paper
Kruk, M., & Jaroniec, M. (2000). Accurate Method for Calculating Mesopore Size Distributions from Argon Adsorption Data at 87 K Developed Using Model MCM-41 Materials. Chemistry of Materials. https://doi.org/10.1021/cm9905601

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.