The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Acoustic Wave Microsensor Arrays for Vapor Sensing
Abstract
ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTAcoustic Wave Microsensor Arrays for Vapor SensingJay W. GrateView Author Information Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352 Cite this: Chem. Rev. 2000, 100, 7, 2627–2648Publication Date (Web):March 28, 2000Publication History Received24 August 1999Published online28 March 2000Published inissue 1 July 2000https://pubs.acs.org/doi/10.1021/cr980094jhttps://doi.org/10.1021/cr980094jresearch-articleACS PublicationsCopyright © 2000 American Chemical SocietyRequest reuse permissionsArticle Views2635Altmetric-Citations352LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose SUBJECTS:Coating materials,Materials,Polymers,Sensors,Thin films Get e-Alerts
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abraham, M. H. (1993) · Chemical Society Reviews · doi:10.1039/cs9932200073 · Cited by 1,968
Chemometrics: A Practical Guide
Tobias, R. D. (1999) · Technometrics · doi:10.1080/00401706.1999.10485949 · Cited by 1,308
Array-Based Vapor Sensing Using Chemically Sensitive, Carbon Black−Polymer Resistors
Lonergan, M. C., Severin, E. J., Doleman, B. J., Beaber, S. A., Grubbs, R. H., & Lewis, N. S. (1996) · Chemistry of Materials · doi:10.1021/cm960036j · Cited by 633
Error propagation and figures of merit for quantification by solving matrix equations
Lorber, A. (1986) · Analytical Chemistry · doi:10.1021/ac00297a042 · Cited by 488
IEICE transactions on electronics
電子情報通信学会 (1992) · Institute of Electronics, Information and Communication Engineers eBooks · Cited by 332
Martin, S. J., Frye, G. C., & Senturia, S. D. (1994) · Analytical Chemistry · doi:10.1021/ac00086a003 · Cited by 332
Randomly Ordered Addressable High-Density Optical Sensor Arrays
Michael, K. L., Taylor, L. C., Schultz, S. L., & Walt, D. R. (1998) · Analytical Chemistry · doi:10.1021/ac971343r · Cited by 325
Thickness-shear-mode acoustic wave sensors in the liquid phase. A review
Thompson, M., Kipling, A. L., Duncan-Hewitt, W. C., Rajaković, L. V., & Čavić-Vlasak, B. A. (1991) · The Analyst · doi:10.1039/an9911600881 · Cited by 324
Abraham, M. H., Whiting, G. S., Doherty, R. M., & Shuely, W. J. (1991) · Journal of Chromatography A · doi:10.1016/0021-9673(91)85158-c · Cited by 287
New Organic Materials Suitable for Use in Chemical Sensor Arrays
Crooks, R. M., & Ricco, A. J. (1998) · Accounts of Chemical Research · doi:10.1021/ar970246h · Cited by 279
Wells, M., & Crooks, R. M. (1996) · Journal of the American Chemical Society · doi:10.1021/ja960097i · Cited by 276
Janata, J., Josowicz, M., & DeVaney, D. M. (1994) · Analytical Chemistry · doi:10.1021/ac00084a010 · Cited by 268
Grate, J. W., Snow, A., Ballantine, D. S., Wohltjen, H., Abraham, M. H., McGill, R. A., & Sasson, P. (1988) · Analytical Chemistry · doi:10.1021/ac00160a010 · Cited by 246
Self-citationDetermination of complex shear modulus with thickness shear mode resonators
Lucklum, R., Behling, C., Cernosek, R. W., & Martin, S. J. (1997) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/30/3/006 · Cited by 183
Kepley, L. J., Crooks, R. M., & Ricco, A. J. (1992) · Analytical Chemistry · doi:10.1021/ac00048a018 · Cited by 171
Rapid Analyte Recognition in a Device Based on Optical Sensors and the Olfactory System
White, J., Kauer, J. S., Dickinson, T. A., & Walt, D. R. (1996) · Analytical Chemistry · doi:10.1021/ac9511197 · Cited by 171
A comparison study of chemical sensor array pattern recognition algorithms
Shaffer, R. E., Rose‐Pehrsson, S. L., & McGill, R. A. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00780-6 · Cited by 151
Multicomponent analysis using an array of piezoelectric crystal sensors
Carey, W. P., Beebe, K. R., & Kowalski, B. R. (1987) · Analytical Chemistry · doi:10.1021/ac00138a010 · Cited by 151
Nakamoto, T., Fukuda, A., & Moriizumi, T. (1993) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)80030-f · Cited by 134
Viscoelastic characterization of electroactive polymer films at the electrode/solution interface
Bandey, H. L., Hillman, A. R., Brown, M. J., & Martin, S. J. (1997) · Faraday Discussions · doi:10.1039/a704278g · Cited by 133
Nakamoto, T., Fukunishi, K., & Moriizumi, T. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80252-u · Cited by 123
Structure-specific collision-induced fragmentations of ceramides cationized with alkali-metal ions
Ann, Q., & Adams, J. (1993) · Analytical Chemistry · doi:10.1021/ac00049a004 · Cited by 109
Determination of polymer shear modulus with quartz crystal resonators
Lucklum, R., & Hauptmann, P. R. (1997) · Faraday Discussions · doi:10.1039/a703127k · Cited by 95
Tokuhisa, H., & Crooks, R. M. (1997) · Langmuir · doi:10.1021/la9705165 · Cited by 85
Göpel, W. (1991) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(91)80172-g · Cited by 71
Grate, J. W., Abraham, M. H., Du, C. M., McGill, R. A., & Shuely, W. J. (1995) · Langmuir · doi:10.1021/la00006a046 · Cited by 65
Self-citationDickert, F. L., & Schuster, O. (1995) · Microchimica Acta · doi:10.1007/bf01244854 · Cited by 54
Chang, S.-M., Iwasaki, Y., Suzuki, M., Tamiya, E., Karube, I., & Muramatsu, H. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83003-2 · Cited by 51
Abraham, M. H., & Walsh, D. P. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)87210-y · Cited by 43
The Polymer-Coated SAW Sensor as a Gravimetric Sensor
Liron, Z., Kaushansky, N., Frishman, G., Kaplan, D., & Greenblatt, J. (1997) · Analytical Chemistry · doi:10.1021/ac9611935 · Cited by 40
Abraham, M. H., Whiting, G. S., Doherty, R. M., Shuely, W. J., & Sakellariou, P. (1992) · Polymer · doi:10.1016/0032-3861(92)90883-x · Cited by 35
Application-specific design of a piezoelectric chemosensor array
Schmautz, A. (1992) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(92)80028-v · Cited by 29
Effect of fluorine substitution on the anodic oxidation of catecholamines and amino acids
Rice, M. E., Moghaddam, B., Creveling, C. R., & Kirk, K. L. (1987) · Analytical Chemistry · doi:10.1021/ac00138a011 · Cited by 28
Parkinson, B. A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja955168c · Cited by 24
Luo, J., Olthuis, W., Bergveld, P., Bos, M. J., & van der Linden, W. E. (1994) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)01170-9 · Cited by 14
Feasibility of surface acoustic wave (SAW) sensor array processing with formal neural networks
Hivert, B., Hoummady, M., Henrioud, J. M., et al. (1994) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)01113-i · Cited by 7
Cited by
Metal–Organic Framework Materials as Chemical Sensors
Kreno, L. E., Leong, K., Farha, O. K., Allendorf, M., Van Duyne, R. P., & Hupp, J. T. (2012) · Chemical Reviews · doi:10.1021/cr200324t · Cited by 7,136
Destruction and Detection of Chemical Warfare Agents
Kim, K., Tsay, O. G., Atwood, D. A., & Churchill, D. G. (2011) · Chemical Reviews · doi:10.1021/cr100193y · Cited by 1,011
Structuring of metal–organic frameworks at the mesoscopic/macroscopic scale
Furukawa, S., Reboul, J., Diring, S., Sumida, K., & Kitagawa, S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00106k · Cited by 897
Optical sensor arrays for chemical sensing: the optoelectronic nose
Askim, J. R., Mahmoudi, M., & Suslick, K. S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60179j · Cited by 886
Morpho butterfly wing scales demonstrate highly selective vapour response
Potyrailo, R. A., Ghiradella, H., Vertiatchikh, A., Dovidenko, K., Cournoyer, J. R., & Olson, E. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.2 · Cited by 562
Metadata
- Authors
- Grate, J. W.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-03-28
- Volume
- 100
- Issue
- 7
- Pages
- 2627-2648
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2010502140
- Cited by
- 400
- References
- 36
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.