Nonisothermal Catalytic Liquefaction of Corn Stalk in Subcritical and Supercritical Water
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The pyrolysis of corn stalk was performed with thermogravimetry (TG), and its liquefaction was investigated in a semicontinuous apparatus with a nonisothermal fluid extraction technique, both with and without sodium carbonate (Na 2 CO 3 ) as a catalyst. The results indicated that the main pyrolysis region of corn stalk is ∼500−650 K and the maximum rate occurs at ∼600 K on the differential thermogravimetry (DTG) curve. The presence of a catalyst has an obvious effect on the pyrolysis, especially in the temperature range of 550−650 K. When more than 1.0 wt % of catalyst was added, the DTG curve is altered greatly, from two peaks to one, for the catalyst, which has a greater effect on hemicellulose than on cellulose and lignin. Kinetic analysis shows that the activation energy in the main pyrolysis range (10−70 wt %) varies with different amounts of catalyst addition. The liquefaction conversion of corn stalk with 3 mL/min of water as a solvent at a pressure of 25 MPa, with or without the addition of 1.0 wt % of Na 2 CO 3, is up to 95.7 and 95.4 wt %, respectively. The catalyst mainly improved the yield of bio-oil, from 33.4% without a catalyst, increasing to 47.2% with 1.0 wt % of Na 2 CO 3 . The catalyst has a positive effect on the liquefaction at relatively higher temperatures and can increase the yield of liquid product, as well as improve the quality of liquid product. More bio-oil and less gas can be obtained with a catalyst than that without a catalyst. A two-stage main reaction may occur for both the pyrolysis and liquefaction of corn stalk under the experimental conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetic Parameters from Thermogravimetric Data
COATS, A. W., & REDFERN, J. P. (1964) · Nature · doi:10.1038/201068a0 · Cited by 6,930
Pyrolysis of Lignins: Experimental and Kinetics Studies
Ferdous, D., Dalai, A. K., Bej, S. K., & Thring, R. W. (2002) · Energy & Fuels · doi:10.1021/ef0200323 · Cited by 310
Cited by
Hydrothermal liquefaction of biomass: A review of subcritical water technologies
Toor, S. S., Rosendahl, L., & Rudolf, A. (2011) · Energy · doi:10.1016/j.energy.2011.03.013 · Cited by 1,840
A comprehensive review on the pyrolysis of lignocellulosic biomass
Dhyani, V., & Bhaskar, T. (2018) · Renewable Energy · doi:10.1016/j.renene.2017.04.035 · Cited by 1,545
Catalytic conversion of lignocellulosic biomass to fine chemicals and fuels
Zhou, C.-H., Xia, X., Lin, C.-X., Tong, D.-S., & Beltramini, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15124j · Cited by 1,420
Thermogravimetric analysis as a new method to determine the lignocellulosic composition of biomass
Carrier, M., Loppinet-Serani, A., Denux, D., Lasnier, J.-M., Ham-Pichavant, F., Cansell, F., & Aymonier, C. (2011) · Biomass and Bioenergy · doi:10.1016/j.biombioe.2010.08.067 · Cited by 780
A review on the current status of various hydrothermal technologies on biomass feedstock
Kumar, M., Olajire Oyedun, A., & Kumar, A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.270 · Cited by 534
Metadata
- Authors
- Song, C., Hu, H., Zhu, S., Wang, G., & Chen, G.
- Venue
- Energy & Fuels
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-12-25
- Volume
- 18
- Issue
- 1
- Pages
- 90-96
- ISSN
- 0887-0624 (ISSN-L)
- 1520-5029
- OpenAlex
- W1965357700
- Cited by
- 134
- References
- 2
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.