Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index; none of the 61 sources its claims cite is checked for support yet.

Potassium, Chlorine, and Sulfur in Ash, Particles, Deposits, and Corrosion during Wood Combustion in a Circulating Fluidized-Bed Boiler

Open access

Abstract

The effect of the addition of chlorine and/or sulfur to the fuel on fly ash composition, deposit formation, and superheater corrosion has been studied during biomass combustion in a circulating fluidized-bed boiler. The chlorine (HCl (aq)) and sulfur (SO 2 (g)) were added in proportions of relevance for the potassium chemistry. The composition of the bottom and the fly ashes was analyzed. Gas and particle measurements were performed downstream of the cyclone before the convection pass and the flue gas composition was recorded in the stack with a series of standard instruments and an FTIR analyzer. At the position downstream of the cyclone, a deposit probe was situated, simulating a superheater tube. Deposits on the probe and initial corrosion were examined. It is concluded that addition of sulfur and chlorine increases the formation of submicron particles leading to deposition of potassium sulfate and chloride. The results compare well with earlier work based on laboratory-scale experiments concerning effects of chlorine and sulfur on potassium chemistry.

Overview

CoChat Summary

## TL;DR

This paper studies how adding HCl and/or SO2 affects potassium, chlorine, sulfur, particle formation, deposits, and initial corrosion during wood combustion in a 12 MWth circulating fluidized-bed boiler. The main finding is that chlorine increases submicron particle formation and KCl deposition, while sulfur shifts potassium chemistry toward sulfate and changes where ash and deposits form.

## Key findings

  • In the boiler mass balance, 30–60% of potassium became strongly bound to the bed material and left with bed ash, 5–15% left with secondary cyclone ash, and 10–25% left with bag-filter ash; the total potassium output was only 60–85% of input.
  • From ash flows and enrichment-factor analysis, the authors estimate that 15–40% of the potassium, corresponding to 0.2–0.6 kg h^-1, deposited on heat-transfer surfaces/inner walls of the boiler.
  • Adding HCl increased fine-particle concentrations substantially; the number size distribution shifted from a peak at 60 nm in the base case to 100 nm in the addition cases, with particle mass increasing by about a factor of 5.
  • In deposits on 304L steel, the base and S cases were dominated by K2SO4 (and K2Ca2(SO4)3 in the base case), the Cl case by KCl, and the Cl + S case by a mixture of KCl and K2SO4; adding HCl increased oxide thickness from 50 nm to 100 nm.

## Methods

  • Experiments were performed in a 12 MWth CFB boiler firing 62–75% wood chips and 25–38% wood pellets at 7–7.5 MWth, with four cases: base, Cl, Cl + S, and S; HCl and SO2 were added in amounts related to potassium chemistry.
  • Ash was sampled from the bed, return leg, secondary cyclone, and bag filters; flue gas was monitored at positions B, E, and G; particles were measured with SMPS and LPI; deposits/corrosion were studied with 304L steel rings on an air-cooled probe at 500°C.
  • Main analyses included ICP-OES/ICP-MS of ash and particles, on-line gas analysis including FTIR for HCl and SO2, XRD for crystalline deposit phases, ESEM/EDX mapping, PCA of elemental maps, and Auger depth profiling.

## Limitations

  • The paper states that ash-flow measurements have uncertainty of 20–25%, and the estimate that 15–40% of potassium deposited on walls is “uncertain” because detailed deposition on tube walls is unknown.
  • The authors note that low ash output made representative fuel sampling difficult, and the measured fuel ash flows had 20–25% uncertainty.
  • Evident from the text: some conclusions about deposition and corrosion are based on short exposures (15 min to 12 h) and on a single probe location, so they do not fully quantify long-term boiler behavior.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1021/ef060306c

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Schematic description of the CFB: (1) combustion chamber; (2) fuel feed chute; (3) primary air to air plenum; (4) secondary air inlet at 2.1 m; (5) bottom ash removal; (6) hot primary cyclone; (7) particle return leg; (8) particle seal; (9) heat exchanger; (10) cold secondary cyclone; (11) secondary cyclone ash removal; (12) bag filters; (13) filter ash removal; (14) flue gas fan; (15) sand bin; (16) lime bin; (17) fuel bunkers; (18) air fan; and (19) flue gas recirculation fan. Measurement positions A, B, C, D, E, F, and G are indicated.
Figure 1 Schematic description of the CFB: (1) combustion chamber; (2) fuel feed chute; (3) primary air to air plenum; (4) secondary air inlet at 2.1 m; (5) bottom ash removal; (6) hot primary cyclone; (7) particle return leg; (8) particle seal; (9) heat exchanger; (10) cold secondary cyclone; (11) secondary cyclone ash removal; (12) bag filters; (13) filter ash removal; (14) flue gas fan; (15) sand bin; (16) lime bin; (17) fuel bunkers; (18) air fan; and (19) flue gas recirculation fan. Measurement positions A, B, C, D, E, F, and G are indicated.From the PDF
Figure 2 Setup for on-line sampling and analysis of particles from the flue gas, including a differential mobility analyzer (DMA) connected to a condensation particle counter (CPC) and a low-pressure impactor (LPI) used to collect samples for subsequent analysis of mass and chemical composition. Abbreviations: T1, T2 ) thermocouples; P ) pressure gauge.
Figure 2 Setup for on-line sampling and analysis of particles from the flue gas, including a differential mobility analyzer (DMA) connected to a condensation particle counter (CPC) and a low-pressure impactor (LPI) used to collect samples for subsequent analysis of mass and chemical composition. Abbreviations: T1, T2 ) thermocouples; P ) pressure gauge.From the PDF
Image 3
From the PDF
Figure 4 Content of K, Cl, and S in ash samples. The sampling position is indicated in each panel.
Figure 4 Content of K, Cl, and S in ash samples. The sampling position is indicated in each panel.From the PDF
Image 5
From the PDF
Figure 6 Particle mass size distributions for total mass and individual elements measured with an LPI at position F downstream of the secondary cyclone in a base case.
Figure 6 Particle mass size distributions for total mass and individual elements measured with an LPI at position F downstream of the secondary cyclone in a base case.From the PDF
Figure 7 Particle mass size distributions of total mass and for K, S, and Ca in samples collected with the LPI at 160 C. The measurements were performed at position F downstream of the secondary cyclone in the base, Cl, and Cl + S cases.
Figure 7 Particle mass size distributions of total mass and for K, S, and Ca in samples collected with the LPI at 160 C. The measurements were performed at position F downstream of the secondary cyclone in the base, Cl, and Cl + S cases.From the PDF
Figure 8 Particle mass size distributions for total mass and for K, S, and Ca in samples collected with the LPI at 800 C. The measurements were performed at position B downstream of the primary cyclone in the Cl, Cl + S, and S cases.
Figure 8 Particle mass size distributions for total mass and for K, S, and Ca in samples collected with the LPI at 800 C. The measurements were performed at position B downstream of the primary cyclone in the Cl, Cl + S, and S cases.From the PDF
Figure 9 Particle number size distributions measured with SMPS at position F downstream of the secondary cyclone in the base, Cl, and Cl + S cases.
Figure 9 Particle number size distributions measured with SMPS at position F downstream of the secondary cyclone in the base, Cl, and Cl + S cases.From the PDF
Figure 10 ESEM and EDX qualitative maps of the sample surface of 304 after 1 h exposure in the Cl case.
Figure 10 ESEM and EDX qualitative maps of the sample surface of 304 after 1 h exposure in the Cl case.From the PDF
Figure 11 ESEM and EDX qualitative maps of the sample surface of 304 after 1 h exposure in the Cl + S case.
Figure 11 ESEM and EDX qualitative maps of the sample surface of 304 after 1 h exposure in the Cl + S case.From the PDF
Figure 12 AES-depth profiles of the thin oxide formed on the leeward side of the 304 samples after 1 h during (a) base case, (b) Cl case, and (c) Cl + S case.
Figure 12 AES-depth profiles of the thin oxide formed on the leeward side of the 304 samples after 1 h during (a) base case, (b) Cl case, and (c) Cl + S case.From the PDF
Figure 13 Elemental enrichment factors of analyzed elements in secondary cyclone and bag filter ash. The ash composition (wt % of dry ash, see Table 1) for wood chips and pellets mixtures was the reference material.
Figure 13 Elemental enrichment factors of analyzed elements in secondary cyclone and bag filter ash. The ash composition (wt % of dry ash, see Table 1) for wood chips and pellets mixtures was the reference material.From the PDF

Verification

Claims the paper makes

0 Valid · 2 Not valid · 33 Not checked · 161 Own results and interpretations

109 more claims

Create a free account to see all 196 claims and to verify the 1 reference still open.

See all claims — free account
  • Probably not a substantial claim. 42
  • It may state two separate claims as one. 52

Create a free account to see these claims.

Citations

Cites

Show all 25 references

Research works printed but not linked: 12

  1. Pettersson J., 2006, Mater. Sci. Forum, 522, 570
  2. Lin W., 2003, Chem. Eng. J., 96, 185
  3. Öhman M., 2000, Energy Fuels, 14, 178
  4. Davidsson K. O., 2002, Fuel, 81, 142
  5. Engvall K., 2001, Report no. 742
  6. Steenari B.-M., 1998, Biomass Bioenergy, 14, 76
  7. Aho M., 2005, Fuel, 84, 212
  8. Henderson P. J., Proceedings of VTT Symposium; Veivo, J., Auerkari, P., Eds.; VTT Technical Research Center of Finland: VTT
  9. Eklund A., 2003, Report no. 832
  10. Åmand L.-E., 2006, Energy Fuels, 20, 1007
  11. Skrifvars B.-J., 1998, Fuel, 77, 70
  12. Pykkönen J., 2003, Fuel Process. Technol., 80, 262

Cited by

See all 94

Metadata

Authors
Davidsson, K. O., Åmand, L.-E., Leckner, B., Kovacevik, B., Svane, M., Hagström, M., Pettersson, J. B. C., Pettersson, J., Asteman, H., Svensson, J.-E., & Johansson, L.-G.
Affiliations
Chalmers University of Technology (SE)
Venue
Energy & Fuels
Published
2006-11-18
Volume
21
Issue
1
Pages
71-81
ISSN
  • 0887-0624 (ISSN-L)
  • 1520-5029
OpenAlex
W1989479932
Cited by
92
References
25
Citations by year
2026: 4 · 2025: 2 · 2024: 4 · 2023: 8 · 2022: 4 · 2021: 5 · 2020: 4 · 2019: 7 · 2018: 5 · 2017: 4 · 2016: 4 · 2015: 4 · 2014: 6 · 2013: 6 · 2012: 10
FWCI
0.26
Type
journal article
Language
en
Open access
Locations
  • Energy & Fuels (publishedVersion)
  • Chalmers Research (Chalmers University of Technology) (submittedVersion)
  • Chalmers Publication Library (Chalmers University of Technology) (submittedVersion)
Topics
  • Physical Sciences › Energy › Fuel Technology › Thermochemical Biomass Conversion Processes
  • Physical Sciences › Engineering › Mechanical Engineering › Coal Combustion and Slurry Processing
  • Physical Sciences › Earth and Planetary Sciences › Geochemistry and Petrology › Coal and Its By-products
Keywords
chlorine, sulfur, fly ash, biomass combustion, circulating fluidized bed boiler, superheater corrosion, deposit formation, potassium sulfate, potassium chloride, submicron particles, flue gas composition, fuel additives

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Potassium, Chlorine, and Sulfur in Ash, Particles, Deposits, and Corrosion during Wood Combustion in a Circulating Fluidized-Bed Boiler. https://app.cochat.ai/papers/10.1021/ef060306c
The paper
Davidsson, K. O., Åmand, L.-E., Leckner, B., Kovacevik, B., Svane, M., Hagström, M., Pettersson, J. B. C., Pettersson, J., Asteman, H., Svensson, J.-E., & Johansson, L.-G. (2007). Potassium, Chlorine, and Sulfur in Ash, Particles, Deposits, and Corrosion during Wood Combustion in a Circulating Fluidized-Bed Boiler. Energy & Fuels. https://doi.org/10.1021/ef060306c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.