Utilization of Sewage-Sludge-Derived Hydrochars toward Efficient Cocombustion with Different-Rank Coals: Effects of Subcritical Water Conversion and Blending Scenarios
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In the absence of prior drying, dewatered sewage sludge (DSS) was directly converted to hydrochars with superior fuel characteristics in subcritical water. Hydrochar derived at 320 °C and 12.0 MPa (SHC-320) was screened for systematic cocombustion with different-rank coals. The results suggest that SHC-320 reduced the activation energy of the blends and altered the main combustion profiles. Meanwhile, blending of SHC-320 induced greater heat loss for higher-rank coals, whereas a higher portion of SHC-320 further improved the ignition reactivity of high-rank coal blends. In the high-temperature region, the value of the pre-exponential factor increased with increasing coal/SHC-320 ratio, resulting in more intense synergistic effects in blends. At a low coal/SHC-320 ratio (30:70), intense antisynergistic effects occurred in cocombustion with low- or high-rank coals. As a result of distinct synergistic interactions, cocombustion with moderate-rank coal achieved the best combustion efficiency among the blends. These findings benefit efficient utilization of DSS as a hydrochar solid fuel in existing cofiring power plants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetic Parameters from Thermogravimetric Data
COATS, A. W., & REDFERN, J. P. (1964) · Nature · doi:10.1038/201068a0 · Cited by 6,930
Effects of various solvents on the liquefaction of biomass to produce fuels and chemical feedstocks
Liu, Z., & Zhang, F.-S. (2008) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.08.009 · Cited by 384
Cited by
Hydrothermal carbonization for energy-efficient processing of sewage sludge: A review
Wang, L., Chang, Y., & Li, A. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.04.011 · Cited by 499
Hydrothermal carbonization of lignocellulosic biomass for carbon rich material preparation: A review
Khan, T. A., Saud, A. S., Jamari, S. S., Rahim, M. H. A., Park, J.-W., & Kim, H.-J. (2019) · Biomass and Bioenergy · doi:10.1016/j.biombioe.2019.105384 · Cited by 469
Peng, C., Zhai, Y., Zhu, Y., Xu, B., Wang, T., Li, C., & Zeng, G. (2016) · Fuel · doi:10.1016/j.fuel.2016.02.068 · Cited by 397
“Residual volatile matter and char/ FC oxidation is mainly attributed to the peak temperature around 500 C [33,34].”
BackgroundMethodNicolae, S. A., Au, H., Modugno, P., Luo, H., Szego, A. E., Qiao, M., Li, L., Yin, W., Heeres, H. J., Berge, N., et al. (2020) · Green Chemistry · doi:10.1039/d0gc00998a · Cited by 311
Wet torrefaction of biomass for high quality solid fuel production: A review
He, C., Tang, C., Li, C., Yuan, J., Tran, K.-Q., Bach, Q.-V., Qiu, R., & Yang, Y. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.097 · Cited by 239
Self-citation
Metadata
- Authors
- He, C., Wang, K., Yang, Y., & Wang, J.-Y.
- Venue
- Energy & Fuels
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-08-25
- Volume
- 28
- Issue
- 9
- Pages
- 6140-6150
- ISSN
- 0887-0624 (ISSN-L)
- 1520-5029
- OpenAlex
- W2067210951
- Cited by
- 59
- References
- 2
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.