Abstract
Air samples from a plant engaged in recycling electronics goods, a factory assembling printed circuit boards, a computer repair facility, offices equipped with computers, and outdoor air have been analyzed with respect to their content of brominated hydrocarbon and phosphate ester flame retardants. Polybrominated diphenyl ethers, polybrominated biphenyls, 1,2-bis(2,4,6-tribromophenoxy)-ethane, tetrabromobisphenol A, and organophosphate esters were all detected in the indoor air samples, with the highest concentrations being detected in air from the recycling plant. In air from the dismantling hall at the recycling plant the average concentrations of decabromodiphenyl ether, tetrabromobisphenol A, and triphenyl phosphate were 38, 55, and 58 pmol/m3, respectively. Significantly higher levels of all of these additives were present in air in the vicinity of the shredder at the dismantling plant. This is the first time that 1,2-bis(2,4,6-tribromophenoxy)-ethane and several arylated phosphate esters are reported to be contaminants of air in occupational settings. At all of the other sites investigated, low levels of flame retardants were detected in the indoor air. Flame retardants associated with airborne particles, present at elevated levels, pose a potential health hazard to the exposed workers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Plastics additives in the indoor environment—flame retardants and plasticizers
Wensing, M., Uhde, E., & Salthammer, T. (2005) · Science of The Total Environment · doi:10.1016/j.scitotenv.2004.10.028 · Cited by 317
Bisphenol A and its analogues in outdoor and indoor air: Properties, sources and global levels
Vasiljevic, T., & Harner, T. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2021.148013 · Cited by 300
Bako-Biro, Z., Wargocki, P., Weschler, C. J., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00218.x · Cited by 180
Emerging Contaminants of Environmental Concern: Source, Transport, Fate, and Treatment
Yan, S., Subramanian, S. B., Tyagi, R. D., Surampalli, R. Y., & Zhang, T. C. (2010) · Practice Periodical of Hazardous, Toxic, and Radioactive Waste Management · doi:10.1061/(asce)hz.1944-8376.0000015 · Cited by 71
Metadata
- Authors
- Sjödin, A., Carlsson, H., Thuresson, K., Sjölin, S., Bergman, Å., & Östman, C.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-12-22
- Volume
- 35
- Issue
- 3
- Pages
- 448-454
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2012339354
- Cited by
- 500
- References
- 0
- FWCI
- 11.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flame Retardants in Indoor Air at an Electronics Recycling Plant and at Other Work Environments. https://app.cochat.ai/papers/10.1021/es000077n
- The paper
- Sjödin, A., Carlsson, H., Thuresson, K., Sjölin, S., Bergman, Å., & Östman, C. (2001). Flame Retardants in Indoor Air at an Electronics Recycling Plant and at Other Work Environments. Environmental Science & Technology. https://doi.org/10.1021/es000077n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.