The DOI matches its Crossref record.
Degradation of Imidacloprid in Water by Photo-Fenton and TiO2 Photocatalysis at a Solar Pilot Plant: A Comparative Study
Abstract
The technical feasibility, mechanisms, and performance of degradation of aqueous imidacloprid have been studied at pilot scale in two well-defined photocatalytic systems of special interest because natural UV light can be used: heterogeneous photocatalysis with titanium dioxide and homogeneous photocatalysis by photo-Fenton. Equivalent pilot-scale and field conditions used for both allowed adequate comparison of the degree of mineralization and toxicity achieved as well as the transformation products generated in route to mineralization by both systems. Ninety-five percent of mineralization (<2.0 mg/L) was reached after 250 min of photocatalytic treatment with Fenton and 450 min with TiO2, meaning that TOC disappears 2.4 times faster with photo-Fenton photocatalytic treatment than with TiO2. The Daphnia Magna test for final residual TOC does not reveal anytoxic behavior. Transformation products evaluated by GC-MS/AED after two SPE procedures and LC-IC were the same in both cases. The main differences between the two processes are in the amount of transformation products (TPs) generated, not in the TPs detected which were always the same. At the end of both processes low concentration (<0.1 mg/L) of 2 pyrrolidinone (transformation product) remains in the dissolution and around 1 mg/L of formate in the case of photo-Fenton.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oller, I., Malato, S., & Sánchez-Pérez, J. A. (2011) · Science of The Total Environment · doi:10.1016/j.scitotenv.2010.08.061 · Cited by 2,406
Self-citationSpasiano, D., Marotta, R., Malato, S., Fernandez-Ibañez, P., & Di Somma, I. (2015) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2014.12.050 · Cited by 723
Self-citationWang, Y., Zhao, H., Li, M., Fan, J., & Zhao, G. (2014) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2013.09.017 · Cited by 451
Photo-Fenton Degradation of Diclofenac: Identification of Main Intermediates and Degradation Pathway
Pérez-Estrada, L. A., Malato, S., Gernjak, W., Agüera, A., Thurman, E. M., Ferrer, I., & Fernández-Alba, A. R. (2005) · Environmental Science & Technology · doi:10.1021/es050794n · Cited by 435
Self-citationWang, Y., Zhao, H., & Zhao, G. (2015) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2014.09.047 · Cited by 410
Metadata
- Authors
- Malato, S., Caceres, J., Agüera, A., Mezcua, M., Hernando, D., Vial, J., & Fernández-Alba, A. R.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-10-03
- Volume
- 35
- Issue
- 21
- Pages
- 4359-4366
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2077154928
- Cited by
- 205
- References
- 0
- FWCI
- 10.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Degradation of Imidacloprid in Water by Photo-Fenton and TiO2 Photocatalysis at a Solar Pilot Plant: A Comparative Study. https://app.cochat.ai/papers/10.1021/es000289k
- The paper
- Malato, S., Caceres, J., Agüera, A., Mezcua, M., Hernando, D., Vial, J., & Fernández-Alba, A. R. (2001). Degradation of Imidacloprid in Water by Photo-Fenton and TiO2 Photocatalysis at a Solar Pilot Plant: A Comparative Study. Environmental Science & Technology. https://doi.org/10.1021/es000289k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.