CoChat

Vacuum Method for Carbonation of Cementitious Wasteforms

Venhuis, Michael A., Reardon, Eric J. · 2001 · Environmental Science & Technology
Cited by 53

The DOI matches its Crossref record.

Abstract

The application of carbonation treatment to cement-based wasteforms as a means to reduce the leachability of entrained undesirable substances, both radioactive and nonradioactive, has been the subject of much study over the past decade. Upon carbonation, hydrated cement phases release their water of hydration and are converted into carbonate minerals. The carbonation process has been shown to reduce the pore size distribution and permeability of the cementitious materials since portions of the original pore network become sites for precipitation of secondary carbonate minerals. As a result, the leachability of entrained contaminants can be markedly reduced. Current methods to carbonate cement-based wasteforms after they have cured rely on exposure to high pressure or supercritical CO2 pressures. In this study, a new low-pressure technique is presented. The method provides more complete carbonation than high-pressure techniques. The principle is to remove the water of reaction as it is produced, thereby maintaining an open pore network to facilitate the transfer of CO2 into the specimen. This is accomplished by conducting the reaction at near-vaccum pressures in the presence of a desiccant. The near-vacuum conditions lower the impedance of water transport from the carbonating specimen to the desiccant due to the large mean free path of the water vapor molecules. The technique was applied to a series of wasteform samples with entrained cationic and anionic waste components. Carbonation penetration depths of up to 11 mm were attained within 45 h of reaction for cylindrical wasteform samples prepared with OPC at a water/cement ratio of 0.60. A carbonation penetration depth of 15 mm was attained in a 6 d reaction of blended cement (OPC and 30% Class 'F' fly ash). In standardized leach tests, cationic waste constituents showed lower leachabilities from carbonated samples than from uncarbonated samples. Anionic waste constituents, however, showed greater leachabilities, and anion leachability increased with the degree of carbonation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es0105156

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Venhuis, M. A., & Reardon, E. J.
Venue
Environmental Science & Technology
Published
2001-09-12
Volume
35
Issue
20
Pages
4120-4125
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2006954519
Cited by
53
References
0
FWCI
18.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.