The DOI matches its Crossref record.
Development and Calibration of a Resin-Based Passive Sampling System for Monitoring Persistent Organic Pollutants in the Atmosphere
Abstract
Responding to a growing need for inexpensive and simple monitoring of persistent organic pollutants (POPs) in the atmosphere, a passive air sampling technique based on the sorption of gaseous pollutants to the sampling resin XAD-2, a styrene−divinylbenzene copolymer, has been developed. A quantitative understanding of the uptake kinetics of the passive air samplers (PAS) was obtained through a combination of field calibration studies, controlled wind tunnel experiments, and flow field simulations. Forty-two PAS were deployed for varying time periods up to 1 yr at three calibration stations in the Laurentian Great Lakes region and the Canadian High Arctic with ongoing conventional air sampling of organochlorine pesticides. The PAS take up quantifiable levels of POPs within a few weeks of deployment, and the amount of chemical collected increases steadily over a 1-yr sampling period. The uptake of POPs by the PAS is controlled by molecular diffusion and independent of wind velocity. The time-averaged air concentrations of organochlorine pesticides derived from the PAS data are comparable with those from HiVol sampling. This study suggests that the XAD-2 resin-based PAS can be used to derive at least semiquantitative information on the vapor-phase concentrations of POPs in the atmosphere and are suitable for the measurements of long-term average concentrations at the levels occurring in remote regions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hexachlorobenzene in the global environment: Emissions, levels, distribution, trends and processes
Barber, J. L., Sweetman, A. J., van Wijk, D., & Jones, K. C. (2005) · Science of The Total Environment · doi:10.1016/j.scitotenv.2005.03.014 · Cited by 428
Neutral polyfluoroalkyl substances in the global Atmosphere
Gawor, A., Shunthirasingham, C., Hayward, S. J., Lei, Y. D., Gouin, T., Mmereki, B. T., Masamba, W., Ruepert, C., Castillo, L. E., Shoeib, M., et al. (2014) · Environ. Sci.: Processes Impacts · doi:10.1039/c3em00499f · Cited by 75
Self-citationKhairy, M., Muir, D., Teixeira, C., & Lohmann, R. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b00186 · Cited by 56
Self-citationParajulee, A., Lei, Y. D., Kananathalingam, A., McLagan, D. S., Mitchell, C. P. J., & Wania, F. (2017) · Water Research · doi:10.1016/j.watres.2017.07.074 · Cited by 32
Self-citation
Metadata
- Authors
- Wania, F., Shen, L., Lei, Y. D., Teixeira, C., & Muir, D. C. G.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-02-20
- Volume
- 37
- Issue
- 7
- Pages
- 1352-1359
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1999967899
- Cited by
- 300
- References
- 0
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and Calibration of a Resin-Based Passive Sampling System for Monitoring Persistent Organic Pollutants in the Atmosphere. https://app.cochat.ai/papers/10.1021/es026166c
- The paper
- Wania, F., Shen, L., Lei, Y. D., Teixeira, C., & Muir, D. C. G. (2003). Development and Calibration of a Resin-Based Passive Sampling System for Monitoring Persistent Organic Pollutants in the Atmosphere. Environmental Science & Technology. https://doi.org/10.1021/es026166c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.