Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 251

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Indirect Electrochemical Treatment of Bisphenol A in Water via Electrochemically Generated Fenton's Reagent

Open access
Gözmen, Belgin, Oturan, Mehmet A., Oturan, Nihal, Erbatur, Oktay·2003·Environmental Science & Technology

Abstract

Bisphenol A (BPA) has been treated with electrochemically generated Fenton's reagent in aqueous medium. Hydroxyl radicals that were formed in Fenton's reagent reacted with the organic substrate producing two different isomers of monohydroxylated product and, upon successive hydroxylation, mainly one dihydroxylated product. Further hydroxylation first degraded one of the aromatic rings, and the side chain thus formed was then cleaved off the other aromatic ring. The second aromatic ring was also degraded upon successive hydroxylations. Small saturated and unsaturated aliphatic acids were the last products prior to mineralization. It was found that use of cuprous/cupric ion pair resulted a faster conversion of BPA and faster mineralization when compared using ferrous/ferric ions, but this happened at the expence of excess electrical charge utilized for an equivalent conversion or mineralization. Degradation by using ferrous/ferric ions was more efficient than cuprous/cupric ions case in terms of total mineralization versus charge utilized, and a mineralization of 82% had been achieved by applying 107.8 mF of charge to a 0.7 mM BPA solution of 0.200 dm3. The rate constant of the monohydroxylation of BPA in the presence of ferrous/ferric ions had been determined as 1.0 x 10(10) M(-1) s(-1) where BPA and salicylic acid competitively reacted with hydroxyl radicals in aqueous medium with the initial concentrations of Fe2+, BPA, and SA of 1.0, 0.5, and 0.5 mM, respectively. In a similar experiment where the initial concentrations of Cu2+, BPA, and SA were 1.0, 0.5, and 0.5 mM, respectively, the corresponding rate constant was determined to be the same as the rate constant obtained for Fe2+ (i.e., 1.0 x 10(10) M(-1) s(-1)). While the use of Cu2+ cannot be advised for processing BPA and similar substrates by using the electro-Fenton technique for both technical and economical reasons, the use of [Fe2+]/[BPA]0 values in the range 3-4 will be sufficient to achieve an efficient mineralization of BPA and similar substrates by the electro-Fenton process in aqueous medium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es034011e

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Gözmen, B., Oturan, M. A., Oturan, N., & Erbatur, O.
Venue
Environmental Science & Technology
Published
2003-07-18
Volume
37
Issue
16
Pages
3716-3723
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2041406277
Cited by
251
References
1
FWCI
14.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.