Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 251

The DOI matches its Crossref record.

Use of Spectroscopic Techniques for Uranium(VI)/Montmorillonite Interaction Modeling

Kowal-Fouchard, A., Drot, R., Simoni, E., Ehrhardt, J. J.·2004·Environmental Science & Technology

Abstract

To experimentally identify both clay sorption sites and sorption equilibria and to understand the retention mechanisms at a molecular level, we have characterized the structure of hexavalent uranium surface complexes resulting from the interaction between the uranyl ions and the surface retention groups of a montmorillonite clay. We have performed laser-induced fluorescence spectroscopy (LIFS) and X-ray photoelectron spectroscopy (XPS) on uranyl ion loaded montmorillonite. These structural results were then compared to those obtained from the study of uranyl ions sorbed onto an alumina and also from U(VI) sorbed on an amorphous silica. This experimental approach allowed for a clear determination of the reactive surface sites of montmorillonite for U(VI) sorption. The lifetime values and the U4f XPS spectra of uranium(VI) sorbed on montmorillonite have shown that this ion is sorbed on both exchange and edge sites. The comparison of U(VI)/clay and U(VI)/oxide systems has determined that the interaction between uranyl ions and montmorillonite edge sites occurs via both [triple bond]AlOH and [triple bond]SiOH surface groups and involves three distinct surface complexes. The surface complexation modeling of the U(VI)/montmorillonite sorption edges was determined using the constant capacitance model and the above experimental constraints. The following equilibria were found to account for the uranyl sorption mechanisms onto montmorillonite for metal concentrations ranged from 10(-6) to 10(-3) M and two ionic strengths (0.1 and 0.5 M): 2[triple bond]XNa + UO2(2+) <==> ([triple bond]X)2UO2 + 2Na+, log K0(exch) = 3.0; [triple bond]Al(OH)2 + UO2(2+) <==> [triple bond]Al(OH)2UO2(2+), log K0(Al) = 14.9; [triple bond]Si(OH)2 + UO2(2+) <==> [triple bond]SiO2UO2 + 2H+, log K0(Si1) = -3.8; and [triple bond]Si(OH)2 + 3UO2(2+) + 5H2O <==> [triple bond]SiO2(UO2)3(OH)5- + 7H+, log K0(Si2) = -20.0.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es0348344

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 251

Metadata

Authors
Kowal-Fouchard, A., Drot, R., Simoni, E., & Ehrhardt, J. J.
Venue
Environmental Science & Technology
Published
2004-01-16
Volume
38
Issue
5
Pages
1399-1407
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2092731656
Cited by
251
References
0
FWCI
5.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of Spectroscopic Techniques for Uranium(VI)/Montmorillonite Interaction Modeling. https://app.cochat.ai/papers/10.1021/es0348344
The paper
Kowal-Fouchard, A., Drot, R., Simoni, E., & Ehrhardt, J. J. (2004). Use of Spectroscopic Techniques for Uranium(VI)/Montmorillonite Interaction Modeling. Environmental Science & Technology. https://doi.org/10.1021/es0348344

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.