Reduction of Aqueous Chromate by Fe(II)/Fe(III) Carbonate Green Rust: Kinetic and Mechanistic Studies
The DOI matches its Crossref record.
Abstract
This work describes the heterogeneous reaction between FeII in carbonate green rust and aqueous chromate, in NaHCO3 solutions at 25 degrees C, and at pH values of 9.3-9.6. Evidence for reduction of CrVI to CrIII and concomitant solid-state oxidation of lattice FeII to FeIII was found from FeII titration and from structural analysis of the solids using FTIR, XRD, SEM, and XPS methods. Results indicate the formation of ferric oxyhydroxycarbonate and the concomitant precipitation of CrIII monolayers at the surface of the iron compound that induce passivation effects and progressive rate limitations. The number of CrIII monolayers formed at the completion of the reaction depends on [FeII]t=0, the molar concentration of FeII(solid) at t=0; on [n(o)]t=0, the molar concentration of reaction sites present at the surface of the solid phase at t=0; and on [CrVI]t=0, the molar concentration of CrVI at t=0. Kinetic data were modeled using a model based on the formation of successive CrIII monolayers, -(d[CrVI]/dt) = sigma(1)j k(i)[S] [CrVI]([n(i - 1)] - [n(i)]) with k(i)[S] (in s(-1) L mol(-1)), the rate coefficient of formation of CrIII monolayer i, and [n(i)] and [n(i - 1)], the molar concentration of CrIII precipitated in monolayer i and monolayer i - 1, respectively. Good matching curves were obtained with kinetic coefficients: k(1)[S] = 5-8 x 10(-4), k(2)[S] = 0.5-3 x 10(-5), and k(3)[S] about 1.7 x 10(-6) s(-1) m(-2) L. The CrVI removal efficiency progressively decreases along with the accumulation of CrIII monolayers at the surface of carbonate green rust particles. In the case of thick green rust particles resulting from the corrosion of iron in permeable reactive barriers, the quantity of FeII readily accessible for efficient CrVI removal should be rather low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Highly Efficient Visible‐Light Plasmonic Photocatalyst Ag@AgBr
Wang, P., Huang, B., Zhang, X., Qin, X., Jin, H., Dai, Y., Wang, Z., Wei, J., Zhan, J., Wang, S., et al. (2009) · Chemistry – A European Journal · doi:10.1002/chem.200802327 · Cited by 592
Usman, M., Byrne, J. M., Chaudhary, A., Orsetti, S., Hanna, K., Ruby, C., Kappler, A., & Haderlein, S. B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00224 · Cited by 484
Enhanced Cr(vi) removal using iron nanoparticle decorated graphene
Jabeen, H., Chandra, V., Jung, S., Lee, J. W., Kim, K. S., & Kim, S. B. (2011) · Nanoscale · doi:10.1039/c1nr10549c · Cited by 375
Xie, B., Shan, C., Xu, Z., Li, X., Zhang, X., Chen, J., & Pan, B. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.09.123 · Cited by 337
Reductive immobilization of chromate in water and soil using stabilized iron nanoparticles
Xu, Y., & Zhao, D. (2007) · Water Research · doi:10.1016/j.watres.2007.02.037 · Cited by 323
Metadata
- Authors
- Legrand, L., El Figuigui, A., Mercier, F., & Chausse, A.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-07-28
- Volume
- 38
- Issue
- 17
- Pages
- 4587-4595
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2074395393
- Cited by
- 154
- References
- 0
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduction of Aqueous Chromate by Fe(II)/Fe(III) Carbonate Green Rust: Kinetic and Mechanistic Studies. https://app.cochat.ai/papers/10.1021/es035447x
- The paper
- Legrand, L., El Figuigui, A., Mercier, F., & Chausse, A. (2004). Reduction of Aqueous Chromate by Fe(II)/Fe(III) Carbonate Green Rust: Kinetic and Mechanistic Studies. Environmental Science & Technology. https://doi.org/10.1021/es035447x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.