Cited by 194TiO2 Photocatalysis and Solar CellsArsenic contamination and mitigationAdvanced oxidation water treatment

Oxidation Mechanism of As(III) in the UV/TiO2 System: Evidence for a Direct Hole Oxidation Mechanism

Yoon, Sung-Hwan, Lee, Jai H.·2005·Environmental Science & Technology

Abstract

Although it is well-known that As(III) is oxidized to As(V) in the UV/TiO2 system, the main oxidant for that reaction is still not clear. Accordingly, the present study aims at reinvestigating the TiO2-photocatalyzed oxidation mechanism of As(III). We performed a series of As(II) oxidation experiments by using UV-C/H2O2 and UV-A/TiO2, focusing on the effects of competing compounds. The experiment with UV-C/H2O2 indicated that HO2*/O2-* is not an effective oxidant of As(III) in the homogeneous phase. The effects of oxalate, formate, and Cu(II) on the photocatalytic oxidation of As(III) contradicted the controversial hypothesis that HO2*/ O2-* is the main oxidant of As(III) in the UV/TiO2 system. The effect of As(III) on the TiO2-photocatalyzed oxidations of benzoate, terephthalate, and formate was also incompatible with the superoxide-based As(II) oxidation mechanism. Instead, the experimental observations implied that OH* and/or the positive hole are largely responsible forthe oxidation of As(III) in the UV/TiO2 system. To determine which species plays a more significant role, the effects of methanol and iodide were tested. Since excess methanol did not retard the oxidation rate of As(III), OH* seems not to be the main oxidant. Therefore, the best rationale regarding the oxidation mechanism of As(III) in the UV/TiO2 system seems to be the direct electron transfer between As(III) and positive holes. Only with this mechanism, it was possible to explain the data of this study. Besides the mechanistic aspect, an application method for this technology was sought. The usage of UV/TiO2 for oxidizing As(II) requires a posttreatment in which both As(V) and TiO2 should be removed from water. For this objective, we applied FeCl3 and AIK(SO4)2 as coagulants, and the result implied that the combined usage of TiO2 and coagulation might be a feasible solution to treat arsenic contamination around the world.

Integrity signals

Registry

Crossref · 10.1021/es051148r

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yoon, S.-H., & Lee, J. H.
Affiliations
Gwangju Institute of Science and Technology (KR)
Corresponding author
Lee, Jai H.
Venue
Environmental Science & Technology
Published
2005-11-11
Volume
39
Issue
24
Pages
9695-9701
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2040610712
Cited by
194
References
1
Citations by year
2025: 2 · 2024: 8 · 2023: 5 · 2022: 11 · 2021: 15 · 2020: 10 · 2019: 9 · 2018: 10 · 2017: 14 · 2016: 16 · 2015: 11 · 2014: 12 · 2013: 11 · 2012: 20
FWCI
3.15
Type
journal article
Language
en
Open access
closed
Locations
  • Environmental Science & Technology (publishedVersion)
  • PubMed (publishedVersion)
Funders
Gwangju Institute of Science and Technology
Topics
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › TiO2 Photocatalysis and Solar Cells
  • Physical Sciences › Environmental Science › Environmental Chemistry › Arsenic contamination and mitigation
  • Physical Sciences › Environmental Science › Water Science and Technology › Advanced oxidation water treatment
Keywords
arsenic(III) oxidation, UV/TiO2 photocatalysis, electron transfer mechanism, superoxide, hydroxyl radicals, arsenic removal from water, coagulation, ferric chloride, potassium aluminum sulfate
MeSH terms
Adsorption, Alum Compounds, Arsenic, Catalysis, Chlorides, Ferric Compounds, Hydrogen Peroxide, Oxidants, Photochemical, Oxidation-Reduction, Oxygen, Photochemistry, Time Factors, Titanium, Ultraviolet Rays, Hydroxyl Radical, Water Purification

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review