The DOI matches its Crossref record.
A Novel Electro-Fenton Process for Water Treatment: Reaction-controlled pH Adjustment and Performance Assessment
Abstract
A novel electro-Fenton (E-Fenton) process was developed, in which the desired pH for an effective E-Fenton reaction and for a neutral treated media could be obtained by utilizing the reaction-released H+ and OH- in stead of chemical addition. In the laboratory-scale process using three chambers, the substrate solution pH > 4.0 was designed to be adjusted in situ through three sequencing steps: (I) pH reduction, (II) pH keeping for the effective E-Fenton reaction, and (III) pH recovery to neutral while the E-Fenton reaction continued. Experimental results demonstrated that such three-step pH adjustment was successfully achieved in this novel E-Fenton process, and that the pH adjustment was controlled by the E-Fenton reaction process. The performance of the novel process was assessed in terms of dimethyl phthalate (DMP) degradation in aqueous solution. The results revealed that the novel process was effective to reduce the DMP concentration and the total organic carbon (TOC) at steps II and III. Also, through experiments, the initial DMP solution pH > 4.0 was selected to be reduced to 3.5 in Step I of the process. This pH adjustment not only allowed the E-Fenton reaction to occur in its favorable pH range, but also benefited any potential subsequent biological treatment process or a final discharge. Moreover, the iron species could be recycled in the process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electro-Fenton Process and Related Electrochemical Technologies Based on Fenton’s Reaction Chemistry
Brillas, E., Sirés, I., & Oturan, M. A. (2009) · Chemical Reviews · doi:10.1021/cr900136g · Cited by 3,437
Advanced Oxidation Processes for Wastewater Treatment: Formation of Hydroxyl Radical and Application
WANG, J. L., & XU, L. J. (2012) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2010.507698 · Cited by 1,586
Liu, Y., Zhao, Y., & Wang, J. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.124191 · Cited by 762
Electro-Fenton degradation of synthetic dyes
Panizza, M., & Cerisola, G. (2009) · Water Research · doi:10.1016/j.watres.2008.10.028 · Cited by 377
Su, P., Zhou, M., Lu, X., Yang, W., Ren, G., & Cai, J. (2019) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2018.12.075 · Cited by 313
Electro-Fenton process for water and wastewater treatment
He, H., & Zhou, Z. (2017) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2017.1405673 · Cited by 303
Zhang, G., Gao, Y., Zhang, Y., & Guo, Y. (2010) · Environmental Science & Technology · doi:10.1021/es1011093 · Cited by 301
Wang, C.-T., Hu, J.-L., Chou, W.-L., & Kuo, Y.-M. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.07.023 · Cited by 271
Self-citationMonteil, H., Péchaud, Y., Oturan, N., & Oturan, M. A. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.07.179 · Cited by 267
Bio-Electro-Fenton Process Driven by Microbial Fuel Cell for Wastewater Treatment
Feng, C.-H., Li, F.-B., Mai, H.-J., & Li, X.-Z. (2010) · Environmental Science & Technology · doi:10.1021/es9032925 · Cited by 265
Metadata
- Authors
- Liu, H., Wang, C., Xiangzhong, Xuan, X., Jiang, C., & Cui, H.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-03-14
- Volume
- 41
- Issue
- 8
- Pages
- 2937-2942
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1993822075
- Cited by
- 171
- References
- 0
- FWCI
- 11.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.