Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 529

The DOI matches its Crossref record.

Ionic Strength and Composition Affect the Mobility of Surface-Modified Fe0 Nanoparticles in Water-Saturated Sand Columns

Saleh, Navid, Kim, Hye-Jin, Phenrat, Tanapon, Matyjaszewski, Krzysztof, Tilton, Robert D., Lowry, Gregory V.·2008·Environmental Science & Technology

Abstract

The surfaces of nanoscale zerovalent iron (NZVI) used for groundwater remediation must be modified to be mobile in the subsurface for emplacement. Adsorbed polymers and surfactants can electrostatically, sterically, or electrosterically stabilize nanoparticle suspensions in water, but their efficacy will depend on groundwater ionic strength and cation type as well as physical and chemical heterogeneities of the aquifer material. Here, the effect of ionic strength and cation type on the mobility of bare, polymer-, and surfactant-modified NZVI is evaluated in water-saturated sand columns at low particle concentrations where filtration theory is applicable. NZVI surface modifiers include a high molecular weight (MW) (125 kg/mol) poly(methacrylic acid)-b-(methyl methacrylate)-b-(styrene sulfonate) triblock copolymer (PMAA-PMMA-PSS), polyaspartate which is a low MW (2-3 kg/mol) biopolymer, and the surfactant sodium dodecyl benzene sulfonate (SDBS, MW = 348.5 g/mol). Bare NZVI with an apparent zeta-potential of -30 +/- 3 mV was immobile. Polyaspartate-modified nanoiron (MRNIP) with an apparent zeta-potential of -39 +/- 1 mV was mobile at low ionic strengths (< 40 mM for Na+ and < 0.5 mM for Ca2+), and had a critical deposition concentration (CDC) of approximately 770 mM Na+ and approximately 4 mM for Ca2+. SDBS-modified NZVI with a similar apparent zeta-potential (-38.3 +/- 0.9 mV) showed similar behavior (CDC approximately 350 mM for Na+ and approximately 3.5 mM for Ca2+). Triblock copolymer-modified NZVI had the highest apparent zeta-potential (-50 +/- 1.2 mV), the greatest mobility in porous media, and a CDC of approximately 4 M for Na+ and approximately 100s of mM for Ca2+. The high mobility and CDC is attributed to the electrosteric stabilization afforded by the triblock copolymer but not the other modifiers which provide primarily electrostatic stabilization. Thus, electrosteric stabilization provides the best resistance to changing electrolyte conditions likely to be encountered in real groundwater aquifers, and may provide transport distances of 10s to 100s of meters in unconsolidated sandy aquifers at injection velocities used for emplacement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es071936b

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Saleh, N., Kim, H.-J., Phenrat, T., Matyjaszewski, K., Tilton, R. D., & Lowry, G. V.
Venue
Environmental Science & Technology
Published
2008-04-05
Volume
42
Issue
9
Pages
3349-3355
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W1996232062
Cited by
529
References
0
FWCI
20.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.