The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Selective Removal of Cu(II) Ions by Using Cation-exchange Resin-Supported Polyethyleneimine (PEI) Nanoclusters
Abstract
A novel hybrid adsorbent D001-PEI was fabricated for selective Cu(II) removal by immobilizing soluble polyethyleneimine (PEI) nanoclusters within a macroporous cation exchange resin D001. Negligible release of PEI nanoclusters unexpectedly observed during operation may result from the porous cross-linking nature of D-001 as well as the electrostatic attraction between PEI and D001. Increasing solution pH from 1 to 6 results in more favorable Cu(II) retention by D001-PEI, and Cu(II) adsorption onto D001-PEI follows the Langmuir model and the pseudosecond-order kinetic model well. Compared to the host cation exchanger D001, D001-PEI displays more preferable adsorption toward Cu(II) in the presence of competing Mg(2+), Ca(2+), Sr(2+) at greater levels in solution. Fixed-bed adsorption runs showed that Cu(II) sequestration on D001-PEI could result in its conspicuous decrease from 5 mg/L to below 0.01 mg/L. Also, the spent hybrid adsorbent can be readily regenerated by 6-8 BV HCl (0.2 mol/L)-NaCl (0.5 mol/L) binary solution for repeated use with negligible capacity loss. The results reported herein validate that D001-PEI is a promising adsorbent for enhanced removal of Cu(II) and other heavy metals from waste effluents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physico–chemical treatment techniques for wastewater laden with heavy metals
Kurniawan, T. A., Chan, G. Y. S., Lo, W.-H., & Babel, S. (2006) · Chemical Engineering Journal · doi:10.1016/j.cej.2006.01.015 · Cited by 2,072
Da̧browski, A., Hubicki, Z., Podkościelny, P., & Robens, E. (2004) · Chemosphere · doi:10.1016/j.chemosphere.2004.03.006 · Cited by 1,717
Heavy metal adsorption onto agro-based waste materials: a review
Demirbas, A. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.01.024 · Cited by 1,566
Cited by
Cui, L., Wang, Y., Gao, L., Hu, L., Yan, L., Wei, Q., & Du, B. (2015) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.06.043 · Cited by 716
Amino modification of biochar for enhanced adsorption of copper ions from synthetic wastewater
Yang, G.-X., & Jiang, H. (2014) · Water Research · doi:10.1016/j.watres.2013.09.050 · Cited by 644
Nanomaterials-enabled water and wastewater treatment
Zhang, Y., Wu, B., Xu, H., Liu, H., Wang, M., He, Y., & Pan, B. (2016) · NanoImpact · doi:10.1016/j.impact.2016.09.004 · Cited by 417
Self-citationSurface engineered magnetic nanoparticles for removal of toxic metal ions and bacterial pathogens
Singh, S., Barick, K. C., & Bahadur, D. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.06.074 · Cited by 348
PEI-grafted magnetic porous powder for highly effective adsorption of heavy metal ions
Pang, Y., Zeng, G., Tang, L., Zhang, Y., Liu, Y., Lei, X., Li, Z., Zhang, J., & Xie, G. (2011) · Desalination · doi:10.1016/j.desal.2011.08.001 · Cited by 329
Metadata
- Authors
- Chen, Y., Pan, B., Li, H., Zhang, W., Lv, L., & Wu, J.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-04-07
- Volume
- 44
- Issue
- 9
- Pages
- 3508-3513
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1994695694
- Cited by
- 229
- References
- 3
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.