The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Doubled Power Density from Salinity Gradients at Reduced Intermembrane Distance
Open accessAbstract
The mixing of sea and river water can be used as a renewable energy source. The Gibbs free energy that is released when salt and fresh water mix can be captured in a process called reverse electrodialysis (RED). This research investigates the effect of the intermembrane distance and the feedwater flow rate in RED as a route to double the power density output. Intermembrane distances of 60, 100, 200, and 485 μm were experimentally investigated, using spacers to impose the intermembrane distance. The generated (gross) power densities (i.e., generated power per membrane area) are larger for smaller intermembrane distances. A maximum value of 2.2 W/m(2) is achieved, which is almost double the maximum power density reported in previous work. In addition, the energy efficiency is significantly higher for smaller intermembrane distances. New improvements need to focus on reducing the pressure drop required to pump the feedwater through the RED-device using a spacerless design. In that case power outputs of more than 4 W per m(2) of membrane area at small intermembrane distances are envisaged.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Fluid Dynamics
Batchelor, G. K. (2000) · doi:10.1017/cbo9780511800955 · Cited by 12,360
Electrodialysis, a mature technology with a multitude of new applications
Strathmann, H. (2010) · Desalination · doi:10.1016/j.desal.2010.04.069 · Cited by 1,545
Mass transfer and pressure loss in spiral wound modules
Schock, G., & Miquel, A. (1987) · Desalination · doi:10.1016/0011-9164(87)90107-x · Cited by 674
Salinity-gradient power: Evaluation of pressure-retarded osmosis and reverse electrodialysis
Post, J. W., Veerman, J., Hamelers, H. V. M., Euverink, G. J. W., Metz, S. J., Nymeijer, K., & Buisman, C. J. N. (2007) · Journal of Membrane Science · doi:10.1016/j.memsci.2006.11.018 · Cited by 616
Energy Recovery from Controlled Mixing Salt and Fresh Water with a Reverse Electrodialysis System
Post, J. W., Hamelers, H. V. M., & Buisman, C. J. N. (2008) · Environmental Science & Technology · doi:10.1021/es8004317 · Cited by 542
Current status of ion exchange membranes for power generation from salinity gradients
DLUGOLECKI, P., NYMEIJER, K., METZ, S., & WESSLING, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2008.03.037 · Cited by 537
International energy outlook 1999
Energy Information Administration, O. O. I. A. A. F. (1999) · doi:10.2172/345025 · Cited by 464
Electric Power from Differences in Salinity: The Dialytic Battery
Weinstein, J. N., & Leitz, F. B. (1976) · Science · doi:10.1126/science.191.4227.557 · Cited by 403
Practical Potential of Reverse Electrodialysis As Process for Sustainable Energy Generation
Długołȩcki, P., Gambier, A., Nijmeijer, K., & Wessling, M. (2009) · Environmental Science & Technology · doi:10.1021/es9009635 · Cited by 370
Self-citationVeerman, J., de Jong, R. M., Saakes, M., Metz, S. J., & Harmsen, G. J. (2009) · Journal of Membrane Science · doi:10.1016/j.memsci.2009.05.047 · Cited by 329
Self-citation
Cited by
Membrane-based processes for sustainable power generation using water
Logan, B. E., & Elimelech, M. (2012) · Nature · doi:10.1038/nature11477 · Cited by 1,644
Recent developments in forward osmosis: Opportunities and challenges
Zhao, S., Zou, L., Tang, C. Y., & Mulcahy, D. (2012) · Journal of Membrane Science · doi:10.1016/j.memsci.2011.12.023 · Cited by 1,355
Electrodialysis desalination for water and wastewater: A review
Al-Amshawee, S., Yunus, M. Y. B. M., Azoddein, A. A. M., Hassell, D. G., Dakhil, I. H., & Hasan, H. A. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.122231 · Cited by 964
High-Performance Ionic Diode Membrane for Salinity Gradient Power Generation
Gao, J., Guo, W., Feng, D., Wang, H., Zhao, D., & Jiang, L. (2014) · Journal of the American Chemical Society · doi:10.1021/ja503692z · Cited by 615
Campione, A., Gurreri, L., Ciofalo, M., Micale, G., Tamburini, A., & Cipollina, A. (2018) · Desalination · doi:10.1016/j.desal.2017.12.044 · Cited by 588
Recent developments and future perspectives of reverse electrodialysis technology: A review
Mei, Y., & Tang, C. Y. (2018) · Desalination · doi:10.1016/j.desal.2017.10.021 · Cited by 499
Materials and membrane technologies for water and energy sustainability
Le, N. L., & Nunes, S. P. (2016) · Sustainable Materials and Technologies · doi:10.1016/j.susmat.2016.02.001 · Cited by 432
Membrane technology in renewable-energy-driven desalination
Ali, A., Tufa, R. A., Macedonio, F., Curcio, E., & Drioli, E. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.047 · Cited by 431
Salinity Gradients for Sustainable Energy: Primer, Progress, and Prospects
Yip, N. Y., Brogioli, D., Hamelers, H. V. M., & Nijmeijer, K. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b03448 · Cited by 388
Self-citationZhang, Z., He, L., Zhu, C., Qian, Y., Wen, L., & Jiang, L. (2020) · Nature Communications · doi:10.1038/s41467-020-14674-6 · Cited by 365
Tufa, R. A., Pawlowski, S., Veerman, J., Bouzek, K., Fontananova, E., di Profio, G., Velizarov, S., Goulão Crespo, J., Nijmeijer, K., & Curcio, E. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.04.111 · Cited by 312
Self-citationFouling in reverse electrodialysis under natural conditions
Vermaas, D. A., Kunteng, D., Saakes, M., & Nijmeijer, K. (2013) · Water Research · doi:10.1016/j.watres.2012.11.053 · Cited by 273
Self-citationBesha, A. T., Gebreyohannes, A. Y., Tufa, R. A., Bekele, D. N., Curcio, E., & Giorno, L. (2017) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2017.04.027 · Cited by 264
Self-Powered Multifunction Ionic Skins Based on Gradient Polyelectrolyte Hydrogels
Xia, M., Pan, N., Zhang, C., Zhang, C., Fan, W., Xia, Y., Wang, Z., & Sui, K. (2022) · ACS Nano · doi:10.1021/acsnano.1c11505 · Cited by 138
Metadata
- Authors
- Vermaas, D. A., Saakes, M., & Nijmeijer, K.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-07-20
- Volume
- 45
- Issue
- 16
- Pages
- 7089-7095
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1985545136
- Cited by
- 411
- References
- 20
- FWCI
- 10.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.