The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
PAH Molecular Diagnostic Ratios Applied to Atmospheric Sources: A Critical Evaluation Using Two Decades of Source Inventory and Air Concentration Data from the UK
Abstract
Molecular diagnostic ratios (MDRs)-the ratios of defined pairs of individual compounds-have been widely used as markers of different source categories of polycyclic aromatic hydrocarbons (PAHs). However, it is well-known that variations in combustion conditions and environmental degradation processes can cause substantial variability in the emission and degradation of individual compounds, potentially undermining the application of MDRs as reliable source apportionment tools. The United Kingdom produces a national inventory of atmospheric emissions of PAHs, and has an ambient air monitoring program at a range of rural, semirural, urban, and industrial sites. The inventory and the monitoring data are available over the past 20 years (1990-2010), a time frame that has seen known changes in combustion type and source. Here we assess 5 MDRs that have been used in the literature as source markers. We examine the spatial and temporal variability in the ratios and consider whether they are responsive to known differences in source strength and types between sites (on rural-urban gradients) and to underlying changes in national emissions since 1990. We conclude that the use of these 5 MDRs produces contradictory results and that they do not respond to known differences (in time and space) in atmospheric emission sources. For example, at a site near a motorway and far from other evident emission sources, the use of MDRs suggests "non-traffic" emissions. The ANT/(ANT + PHE) ratio is strongly seasonal at some sites; it is the most susceptible MDR to atmospheric processes, so these results illustrate how weathering in the environment will undermine the effectiveness of MDRs as markers of source(s). We conclude that PAH MDRs can exhibit spatial and temporal differences, but they are not valid markers of known differences in source categories and type. Atmospheric sources of PAHs in the UK are probably not dominated by any single clear and strong source type, so the mixture of PAHs in air is quickly "blended" away from the influence of the few major point sources which exist and further weathered in the environment by atmospheric reactions and selective loss processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yunker, M. B., Macdonald, R. W., Vingarzan, R., Mitchell, R. H., Goyette, D., & Sylvestre, S. (2002) · Organic Geochemistry · doi:10.1016/s0146-6380(02)00002-5 · Cited by 4,259
Global atmospheric emission inventory of polycyclic aromatic hydrocarbons (PAHs) for 2004
Zhang, Y., & Tao, S. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.10.050 · Cited by 888
Galarneau, E. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.07.025 · Cited by 460
Zhang, X. L., Tao, S., Liu, W. X., Yang, Y., Zuo, Q., & Liu, S. Z. (2005) · Environmental Science & Technology · doi:10.1021/es0513741 · Cited by 332
Lee, R. G. M., Coleman, P., Jones, J. L., Jones, K. C., & Lohmann, R. (2005) · Environmental Science & Technology · doi:10.1021/es048745i · Cited by 281
Self-citationTsapakis, M., & Stephanou, E. G. (2005) · Environmental Pollution · doi:10.1016/j.envpol.2004.05.012 · Cited by 271
Katsoyiannis, A., Terzi, E., & Cai, Q.-Y. (2007) · Chemosphere · doi:10.1016/j.chemosphere.2007.05.084 · Cited by 261
Self-citationOdabasi, M., Cetin, E., & Sofuoglu, A. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.05.051 · Cited by 251
Dvorská, A., Lammel, G., & Klánová, J. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.09.063 · Cited by 215
Wang, W., Massey Simonich, S. L., Xue, M., Zhao, J., Zhang, N., Wang, R., Cao, J., & Tao, S. (2010) · Environmental Pollution · doi:10.1016/j.envpol.2010.01.021 · Cited by 212
Cited by
PAH diagnostic ratios for the identification of pollution emission sources
Tobiszewski, M., & Namieśnik, J. (2012) · Environmental Pollution · doi:10.1016/j.envpol.2011.10.025 · Cited by 1,881
Biological machinery for polycyclic aromatic hydrocarbons degradation: A review
Imam, A., Kumar Suman, S., Kanaujia, P. K., & Ray, A. (2022) · Bioresource Technology · doi:10.1016/j.biortech.2021.126121 · Cited by 208
Metadata
- Authors
- Katsoyiannis, A., Sweetman, A. J., & Jones, K. C.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-09-02
- Volume
- 45
- Issue
- 20
- Pages
- 8897-8906
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2087035051
- Cited by
- 350
- References
- 20
- FWCI
- 15.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PAH Molecular Diagnostic Ratios Applied to Atmospheric Sources: A Critical Evaluation Using Two Decades of Source Inventory and Air Concentration Data from the UK. https://app.cochat.ai/papers/10.1021/es202277u
- The paper
- Katsoyiannis, A., Sweetman, A. J., & Jones, K. C. (2011). PAH Molecular Diagnostic Ratios Applied to Atmospheric Sources: A Critical Evaluation Using Two Decades of Source Inventory and Air Concentration Data from the UK. Environmental Science & Technology. https://doi.org/10.1021/es202277u
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.