Equilibrium Partition Coefficients of Diverse Polar and Nonpolar Organic Compounds to Polyoxymethylene (POM) Passive Sampling Devices
The DOI matches its Crossref record.
Abstract
Equilibrium passive samplers (EPS) based on polyoxymethylene (POM) are increasingly used for determining freely dissolved water and pore water concentrations of hydrophobic organic compounds in the environment. Unlike other polymeric materials commonly used as EPS, namely poly(dimethylsiloxane) (PDMS) and low-density polyethylene (PE), POM is a polar polymer, containing repeating H-bond accepting ether units. Thus, POM is expected to be a more sensitive EPS than PDMS and PE for polar, H-bond donating compounds, such as many hormones, pharmaceuticals, and biocides. To better characterize the sorption capacity of POM for diverse polar and apolar compounds, equilibrium POM-water partition coefficients, K(POM/w), were measured for 56 compounds, including several classes of polar compounds and organochlorine pesticides. Using this data set and literature data, various POM-partitioning models were calibrated and validated for their ability to predict K(POM/w). The best performing models tested were an Abraham descriptor based polyparameter linear free energy relationship (PP-LFER) (SD = 0.24 log units) and COSMOthermX (SD = 0.37 log units). The performance of SPARC (SD = 0.61 log units) and log-log correlations with K(ow) (SD = 0.49 log units) were lower. A comparison with PDMS and PE confirmed expectations that POM exhibits a higher sensitivity for H-bond donating polar compounds than PDMS and PE do for these compounds. These findings expand the domain of chemicals for which POM can be used as an EPS sampler, and demonstrate that POM is as suitable a passive sampler for many polar organic compounds as it is for hydrophobic organic compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Atugoda, T., Vithanage, M., Wijesekara, H., Bolan, N., Sarmah, A. K., Bank, M. S., You, S., & Ok, Y. S. (2021) · Environment International · doi:10.1016/j.envint.2020.106367 · Cited by 561
Guo, X., Wang, X., Zhou, X., Kong, X., Tao, S., & Xing, B. (2012) · Environmental Science & Technology · doi:10.1021/es301386z · Cited by 418
Sorption Behavior and Mechanisms of Organic Contaminants to Nano and Microplastics
Wang, F., Zhang, M., Sha, W., Wang, Y., Hao, H., Dou, Y., & Li, Y. (2020) · Molecules · doi:10.3390/molecules25081827 · Cited by 314
Applications of Polyparameter Linear Free Energy Relationships in Environmental Chemistry
Endo, S., & Goss, K.-U. (2014) · Environmental Science & Technology · doi:10.1021/es503369t · Cited by 302
Self-citationCalibration and use of the polar organic chemical integrative sampler—a critical review
Harman, C., Allan, I. J., & Vermeirssen, E. L. M. (2012) · Environmental Toxicology and Chemistry · doi:10.1002/etc.2011 · Cited by 300
Metadata
- Authors
- Endo, S., Hale, S. E., Goss, K.-U., & Arp, H. P. H.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-27
- Volume
- 45
- Issue
- 23
- Pages
- 10124-10132
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2062255060
- Cited by
- 117
- References
- 0
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Equilibrium Partition Coefficients of Diverse Polar and Nonpolar Organic Compounds to Polyoxymethylene (POM) Passive Sampling Devices. https://app.cochat.ai/papers/10.1021/es202894k
- The paper
- Endo, S., Hale, S. E., Goss, K.-U., & Arp, H. P. H. (2011). Equilibrium Partition Coefficients of Diverse Polar and Nonpolar Organic Compounds to Polyoxymethylene (POM) Passive Sampling Devices. Environmental Science & Technology. https://doi.org/10.1021/es202894k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.