The DOI matches its Crossref record.
Degradation of Polyamide Nanofiltration and Reverse Osmosis Membranes by Hypochlorite
Abstract
The degradation of polyamide (PA) nanofiltration and reverse osmosis membranes by chlorine needs to be understood in order to develop chlorine-resistant membranes. Coated and uncoated fully aromatic (FA) and piperazine (PIP) semi-aromatic PA membranes were treated with hypochlorite solution and analyzed by X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FTIR). XPS results showed that in chlorine treated FA PA membranes the ratio of bound chlorine to surface nitrogen was 1:1 whereas it was only 1:6 in the case of PIP PA membranes. Surface oxygen of uncoated FA and PIP membranes increased with increasing hypochlorite concentration whereas it decreased for coated FA membranes. High resolution XPS data support that chlorination increased the number of carboxylic groups on the PA surface, which appear to form by hydrolysis of the amide bonds (C(O)-N). FTIR data indicated the disappearance of the amide II band (1541 cm(-1)) and aromatic amide peak (1609 cm(-1)) in both coated and uncoated chlorinated FA membranes, consistent with the N-chlorination suggested by the XPS results. Furthermore, the surface charge of chlorinated membranes at low pH (<6) became negative, consistent with amide-nitrogen chlorination. Chlorination appeared to both increase and decrease membrane hydrophobicity depending on chlorination exposure conditions, which implied that N-chlorination and hydrolysis may be competing processes. The effects of property changes on the membrane performance were also observed for NF90, BW30, and NF270 membranes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fouling in membrane bioreactors: An updated review
Meng, F., Zhang, S., Oh, Y., Zhou, Z., Shin, H.-S., & Chae, S.-R. (2017) · Water Research · doi:10.1016/j.watres.2017.02.006 · Cited by 1,078
The upper bound of thin-film composite (TFC) polyamide membranes for desalination
Yang, Z., Guo, H., & Tang, C. Y. (2019) · Journal of Membrane Science · doi:10.1016/j.memsci.2019.117297 · Cited by 592
Self-citationAsif, M. B., & Zhang, Z. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.129481 · Cited by 580
Choi, W., Choi, J., Bang, J., & Lee, J.-H. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am403790s · Cited by 543
More resilient polyester membranes for high-performance reverse osmosis desalination
Yao, Y., Zhang, P., Sun, F., Zhang, W., Li, M., Sha, G., Teng, L., Wang, X., Huo, M., DuChanois, R. M., et al. (2024) · Science · doi:10.1126/science.adk0632 · Cited by 280
Metadata
- Authors
- Do, V. T., Tang, C. Y., Reinhard, M., & Leckie, J. O.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-05
- Volume
- 46
- Issue
- 2
- Pages
- 852-859
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2061856644
- Cited by
- 464
- References
- 0
- FWCI
- 21.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Degradation of Polyamide Nanofiltration and Reverse Osmosis Membranes by Hypochlorite. https://app.cochat.ai/papers/10.1021/es203090y
- The paper
- Do, V. T., Tang, C. Y., Reinhard, M., & Leckie, J. O. (2012). Degradation of Polyamide Nanofiltration and Reverse Osmosis Membranes by Hypochlorite. Environmental Science & Technology. https://doi.org/10.1021/es203090y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.