The DOI matches its Crossref record.
Highly Active and Stable Ni–Fe Bimetal Prepared by Ball Milling for Catalytic Hydrodechlorination of 4-Chlorophenol
Abstract
A novel Ni-Fe bimetal with high dechlorination activity for 4-chlorophenol (4-CP) was prepared by ball milling (BM) in this study. Increasing Ni content and milling time greatly enhanced the dechlorination activity, which was mainly attributed to the homogeneous distribution of Ni nanoparticles (50-100 nm) in bulk Fe visualized by scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) with image mapping. In comparison with the Ni-Fe bimetal prepared by a chemical solution deposition (CSD) process, the ball milled Ni-Fe bimetal possessed high dechlorination activity and stability before being used up. Dechlorination kinetics indicated that the dechlorination rates of 4-CP increased with increasing Ni-Fe dose but decreased with increasing solution pH. Solution pH had a significant effect on the dechlorination of 4-CP and the passivation of the Ni-Fe bimetal. The enhanced pH during the dechlorination process significantly accelerated the formation of passivating film on the bimetallic surface. The Ni-Fe bimetal at the dose of 60 g/L was reused 10 times without losing dechlorination activity for 4-CP at initial pH less than 6.0, but the gradual passivation was observed at initial pH above 7.0.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The use of zero-valent iron for groundwater remediation and wastewater treatment: A review
Fu, F., Dionysiou, D. D., & Liu, H. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2013.12.062 · Cited by 1,640
Review on nano zerovalent iron (nZVI): From synthesis to environmental applications
Stefaniuk, M., Oleszczuk, P., & Ok, Y. S. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.11.046 · Cited by 935
Jiang, G., Lan, M., Zhang, Z., Lv, X., Lou, Z., Xu, X., Dong, F., & Zhang, S. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b01128 · Cited by 378
Nyabadza, A., McCarthy, É., Makhesana, M., Heidarinassab, S., Plouze, A., Vazquez, M., & Brabazon, D. (2023) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2023.103010 · Cited by 318
Liu, W.-J., Qian, T.-T., & Jiang, H. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.10.062 · Cited by 252
Devi, P., & Saroha, A. K. (2015) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.02.087 · Cited by 168
Li, X., Xing, W., Hu, T., Luo, K., Wang, J., & Tang, W. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214811 · Cited by 138
Metadata
- Authors
- Xu, F., Deng, S., Xu, J., Zhang, W., Wu, M., Wang, B., Huang, J., & Yu, G.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-29
- Volume
- 46
- Issue
- 8
- Pages
- 4576-4582
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2319821088
- Cited by
- 170
- References
- 0
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.