The DOI matches its Crossref record.
Rationalizing Nanomaterial Sizes Measured by Atomic Force Microscopy, Flow Field-Flow Fractionation, and Dynamic Light Scattering: Sample Preparation, Polydispersity, and Particle Structure
Abstract
This study aims to rationalize the variability in the measured size of nanomaterials (NMs) by some of the most commonly applied techniques in the field of nano(eco)toxicology and environmental sciences, including atomic force microscopy (AFM), dynamic light scattering (DLS), and flow field-flow fractionation (FlFFF). A validated sample preparation procedure for size evaluation by AFM is presented, along with a quantitative explanation of the variability of measured sizes by FlFFF, AFM, and DLS. The ratio of the z-average hydrodynamic diameter (d(DLS)) by DLS and the particle height by AFM (d(AFM)) approaches 1.0 for monodisperse samples and increases with sample polydispersity. A polydispersity index of 0.1 is suggested as a suitable limit above which DLS data can no longer be interpreted accurately. Conversion of the volume particle size distribution (PSD) by FlFFF-UV to the number PSD reduces the differences observed between the sizes measured by FlFFF (d(FlFFF)) and AFM. The remaining differences in the measured sizes can be attributed to particle structure (sphericity and permeability). The ratio d(FlFFF)/d(AFM) approaches 1 for small ion-coated NMs, which can be described as hard spheres, whereas d(FlFFF)/d(AFM) deviates from 1 for polymer-coated NMs, indicating that these particles are permeable, nonspherical, or both. These findings improve our understanding of the rather scattered data on NM size measurements reported in the environmental and nano(eco)toxicology literature and provide a tool for comparison of the measured sizes by different techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Ternes, T. A. (2014) · Analytical Chemistry · doi:10.1021/ac500508t · Cited by 2,144
Baruah, B., Gabriel, G. J., Akbashev, M. J., & Booher, M. E. (2013) · Langmuir · doi:10.1021/la305068p · Cited by 391
Wu, J., Jiang, R., Lin, W., & Ouyang, G. (2019) · Environmental Pollution · doi:10.1016/j.envpol.2018.11.055 · Cited by 309
De la Calle, I., Menta, M., & Séby, F. (2016) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2016.09.007 · Cited by 99
Metadata
- Authors
- Baalousha, M., & Lead, J. R.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-05-24
- Volume
- 46
- Issue
- 11
- Pages
- 6134-6142
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2333233678
- Cited by
- 169
- References
- 0
- FWCI
- 14.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rationalizing Nanomaterial Sizes Measured by Atomic Force Microscopy, Flow Field-Flow Fractionation, and Dynamic Light Scattering: Sample Preparation, Polydispersity, and Particle Structure. https://app.cochat.ai/papers/10.1021/es301167x
- The paper
- Baalousha, M., & Lead, J. R. (2012). Rationalizing Nanomaterial Sizes Measured by Atomic Force Microscopy, Flow Field-Flow Fractionation, and Dynamic Light Scattering: Sample Preparation, Polydispersity, and Particle Structure. Environmental Science & Technology. https://doi.org/10.1021/es301167x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.