The DOI matches its Crossref record.
CO2Capture from Simulated Fuel Gas Mixtures Using Semiclathrate Hydrates Formed by Quaternary Ammonium Salts
Abstract
In order to investigate the feasibility of semiclathrate hydrate-based precombustion CO2 capture, thermodynamic, kinetic, and spectroscopic studies were undertaken on the semiclathrate hydrates formed from a fuel gas mixture of H2 (60%) + CO2 (40%) in the presence of quaternary ammonium salts (QASs) such as tetra-n-butylammonium bromide (TBAB) and fluoride (TBAF). The inclusion of QASs demonstrated significantly stabilized hydrate dissociation conditions. This effect was greater for TBAF than TBAB. However, due to the presence of dodecahedral cages that are partially filled with water molecules, TBAF showed a relatively lower gas uptake than TBAB. From the stability condition measurements and compositional analyses, it was found that with only one step of semiclathrate hydrate formation with the fuel gas mixture from the IGCC plants, 95% CO2 can be enriched in the semiclathrate hydrate phase at room temperature. The enclathration of both CO2 and H2 in the cages of the QAS semiclathrate hydrates and the structural transition that results from the inclusion of QASs were confirmed through Raman and (1)H NMR measurements. The experimental results obtained in this study provide the physicochemical background required for understanding selective partitioning and distributions of guest gases in the QAS semiclathrate hydrates and for investigating the feasibility of a semiclathrate hydrate-based precombustion CO2 capture process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Babu, P., Linga, P., Kumar, R., & Englezos, P. (2015) · Energy · doi:10.1016/j.energy.2015.03.103 · Cited by 620
A Review of Non-Thermal Plasma Technology: A novel solution for CO2 conversion and utilization
George, A., Shen, B., Craven, M., Wang, Y., Kang, D., Wu, C., & Tu, X. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109702 · Cited by 497
Review of pre-combustion capture and ionic liquid in carbon capture and storage
Theo, W. L., Lim, J. S., Hashim, H., Mustaffa, A. A., & Ho, W. S. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.09.103 · Cited by 396
Alternative pathways for efficient CO2 capture by hybrid processes—A review
Song, C., Liu, Q., Ji, N., Deng, S., Zhao, J., Li, Y., Song, Y., & Li, H. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.040 · Cited by 349
A Critical Review of CO2 Capture Technologies and Prospects for Clean Power Generation
Sifat, N. S., & Haseli, Y. (2019) · Energies · doi:10.3390/en12214143 · Cited by 226
Metadata
- Authors
- Park, S., Lee, S., Lee, Y., & Seo, Y.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-06-11
- Volume
- 47
- Issue
- 13
- Pages
- 7571-7577
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2314380337
- Cited by
- 163
- References
- 0
- FWCI
- 23.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.